background image

CH. 1 - INFORMATION ON THE DEVICE   

 

 1.1 - General precautions 

The ozone generator must be used only by trained staff, who must be entirely familiar 
with the contents of this manual. 

New staff must be trained in advance on how to use the machine. 

Strictly avoid using the device when other people or animals are present; ventilate the 
area thoroughly before allowing them to spend time in it again. 

When programming the device for use, concentrate on the job in hand. 

Periodically check the condition of the power cable; a damaged or worn power cable 
poses a serious electrical hazard. 

If the device is or appears to be malfunctioning, do not use it and contact the Support 
Centre immediately. 

Do not attempt to perform repairs yourself but always contact the Service Centre.

 

The user is not authorised to tamper with the machine for any reason whatsoever. 
Contact the Service Centre if you encounter any anomalies. 

Any attempt to dismantle, modify or tamper with any part of the machine by the user or 
unauthorised personnel will immediately void the 

Declaration of Conformity

, invalidate 

the warranty and relieve the Manufacturer of any liability. The manufacturer is also 
relieved of all liability for the consequences of: 



improper use or tampering with the machine by inadequately trained personnel; 



lack of or poor maintenance; 



use of 

non-original

 spare parts not specifically designed for the model; 



total or partial failure to follow the instructions given in this manual; 



treatment of the device’s surfaces with unsuitable products. 

 

1.2 - Safety devices installed on the device 

The safety devices against electrical risks conform to EU Directive 

2014/35 

and the

 

60335/1 

standard. 

The ozone generator is therefore equipped with electrical safety devices both when 
operating and when being cleaned or serviced. 
Nonetheless, there are certain 

“RESIDUAL RISKS”

 that cannot be eliminated entirely; 

they are referred to herein with the word 

“WARNING”

 and concern use, cleaning and 

maintenance of the device when there is a risk of electrocution, fire and ozone (O

3

inhalation due to the presence of people or animals during use. The ozone (O

3

) generated 

can also cause damage such as oxidation of the materials, objects and devices present in 
the treated environments. 

  
1.3 - Description 
1.3.1 - General description 

The ozone generator is designed and built by our company with the precise aim of 
generating ozone from oxygen that is normally found in the air inside premises. It is built to 
ensure that: 

-

 all its parts are sturdy and stable; 

- the circulation fan favours excellent air/ozone exchange.  
If any accident occurs, the manufacturer shall not be held liable if the machine has been 
modified, tampered with, deprived of its safety guards or used for purposes other than the 
intended uses specified by the manufacturer. 

 

 

Summary of Contents for 61051122

Page 1: ...10 2021 Mod OZONE 112MC Production code 61051122 ...

Page 2: ...OPERATING AND MAINTENANCE MANUAL English ...

Page 3: ...d use 1 5 Improper use 1 6 Technical data 1 7 Composition of the generator CH 2 TECHNICAL DATA 7 2 1 Overall dimensions weight specifications CH 3 RECEIVING THE DEVICE 8 3 1 Shipping 3 2 Inspection of the packaging on delivery 3 3 Disposal of packaging CH 4 INSTALLATION 9 4 1 Positioning 4 2 Connection to the power supply 4 3 Wiring diagram 4 3 1 220 240 V 50 Hz CH 5 USING THE DEVICE 10 5 1 Contro...

Page 4: ... of or poor maintenance use of non original spare parts not specifically designed for the model total or partial failure to follow the instructions given in this manual treatment of the device s surfaces with unsuitable products 1 2 Safety devices installed on the device The safety devices against electrical risks conform to EU Directive 2014 35 and the 60335 1 standard The ozone generator is ther...

Page 5: ...a machine for generating ozone intended for other purposes Do not use the device unless it has been properly positioned with all its guards in good working order to prevent the risk of serious personal injury Do not access the components to avoid the risk of electrocution Do not start up the equipment if it is clearly or presumably faulty Before using the device make sure that any potentially haza...

Page 6: ...ndi 3 Emissione O3 OUT 6 Cavo di alimentazione Fig n 2 LE CARATTERISTICHE ELETTRICHE PER LE QUALI E PREDISPOSTA L APPARECCHIO SONO INDICATE IN UNA TARGHETTA APPLICATA SUL RETRO DELLA STESSA PRIMA DI ESEGUIRE L ALLACCIAMENTO VEDERE PUNTO ALLACCIAMENTO ELETTRICO 5 6 2 IN 1 3 O3 OUT 4 ...

Page 7: ... watt 740 Power supply 220 240V 50 Hz Rated O3 production g h 112 Timer min 60 Fan m3 h 165x2 A x B mm 322x145 C x D mm 336x186 E mm 1806 F mm 176 Net weight kg 14 5 the rated data refers to tests conducted in a room with 100 oxygen The actual production is therefore proportional to the percentage of oxygen in the air which is generally around 20 22 ...

Page 8: ...ipping If the packaging shows signs of mishandling impacts or dropping report the damage to the shipping agent within three days of the date of delivery indicated on the documents and draw up a detailed report on any damage to the machine 3 3 Disposal of the packaging The packaging materials cardboard box plastic strap and polystyrene or polyurethane foam can be disposed of together with normal ho...

Page 9: ...g in between Fig 5 Fig n 6 4 2 Connection to the power supply The device comes with a power cable having a cross sectional size of 3x1 5 mm a length of 1 5 m and a Schuko plug Connect the device to the 220 240 V 50 Hz power supply while making sure that the system complies perfectly with the standards and includes a 0 03 A 10 A residual current circuit breaker Moreover check that the information o...

Page 10: ...rogrammed operation without having to intervene on the weekly clock Finder programmer model 12 61 8 230 Ref 2 Fig 7 can be used for adjusting the appliance for cyclical weekly programming To programme the clock on a weekly basis refer to the enclosed instructions from page 12 The Finder programmer model 12 61 8 230 is also equipped with a handy app based programming system for Android and iOS smar...

Page 11: ...iral loads on surfaces objects and in the air To sanitise the environments correctly programme the device on the basis of the respective programming table shown on page 11 The actual O3 production capacity of the device is shown in the technical data table see page 6 and the production is expressed in g h grams per hour All the devices we manufacture are suitable for use in medium sized open space...

Page 12: ... 1 ppm medium sanitisation bacteria 70 viruses 80 fungi animal parasites environmental odours 2 ppm strong sanitisation bacteria 99 viruses and mites 95 moulds animal parasites environmental odours Programming table O3 112 Nominal production Concentration Timer 20 min Timer 40 min Ppm mc mc mq mc Mq mc Mq 112 g h 1 ppm 600 200 1080 360 1320 440 2 ppm 360 120 600 200 1080 240 Timer 60 min ...

Page 13: ...12 ...

Page 14: ...13 ...

Page 15: ...14 ...

Page 16: ...15 ...

Page 17: ...16 ...

Page 18: ...17 ...

Page 19: ...crubbing brushes or anything that may damage the surface of the device Do not introduce tools or brushes inside the device Do not wet the machine or any of its parts nor wash it in a dishwasher 6 2 Maintenance To protect the device against dust build up we recommend storing it in a dry and dust free place for example in its original packaging in a cabinet etc CH 7 MAINTENANCE 7 1 General informati...

Page 20: ...sal The crossed out wheelie bin symbol on the equipment or on its packaging indicates that the product must be disposed of separately from other waste at the end of its useful life The separate waste collection of this device at the end of its life is organised and managed by the manufacturer The user who wishes to dispose of this device must contact the manufacturer and follow the given instructi...

Reviews: