ENGLISH
GB
13
7. FAULTS
The information shown below aims to help with
the identification and correction of any anomalies
and malfunctions which could occur during use.
Some of these problems can be resolved by the
user. For the others, precise competency is
required and they must therefore only be carried
out by qualified staff.
Problem
Causes
Solutions
The refrigerator unit does not start
End of defrosting
it starts after a pause of 3 minutes
Switch-off by means of master
switch
re-started, starts up after 3 minutes
No voltage
check plug, sockets, fuses and
electric mains
Other causes
If the problem persists,
contact the after-sales centre.
The refrigerator unit functions
continuously, cooling insufficiently
Room too hot
air the environment
Dirty condenser
clean the condenser
Insufficient door sealing
check the gaskets
Insufficient quantity of
refrigerant gas
Contact the after-sales
centre.
Hot gas valve partially open
Contact the after-sales
centre.
Resistances always inserted
check timer (only on models with
electric defrosting)
Condenser fan at a standstill
Contact the after-sales
centre.
Evaporator fan at a standstill
Contact the after-sales
centre.
The refrigerator unit does not stop
Probe faulty
Contact the after-sales
centre.
Remote-thermostat or
thermostat faulty
Contact the after-sales
centre.
Presence of ice inside the
evaporator
Drain pipe blocked
disassemble and re-mount the
draining unit after having checked
cleanliness (only on static model)
Appliance not level
use the adjustable feet to level
Hot gas valve failure
Contact the after-sales
centre.
Resistances not functioning
check defrosting activation (only on
models with electric defrosting)
Appliance noise
Persistent vibrations
check there is no contact between
the appliance and other objects
inside or outside