Manufactured By
Miller Refrigeration LLC
7295 50
th
Ave.
Sears, MI49679
231-734-2500
866-825-4013
The Diamond logo is owned by Miller Refrigeration
Troubleshooting
Problem
Likely Cause
Solution
Burner will not
Light
Ignitor will not spark
Reconnect ignitor wire.
Inspect that the spark electrode tip is not
further from burner slots than
⅛
” (see pic-
ture on pg. 8)
Ignitor wire may be shorting out
Inspect the ignitor wire for frays and
tears, and if torn or frayed, call your local
Diamond
dealer to get a replacement.
Is the peizo ignitor functioning
Operate the ignition more often when
lighting. Push the button rapidly until the
flame lights
Ignitor sparks, but
burner will not
light or stay lit.
Thermocouple may be bad
If flame does not stay lit when you release
the gas safety valve, replace the thermo-
couple.
Is the gas pressure correct
Have a qualified technician check your gas
pressure. i.e. local propane company. The
gas pressure should be 11” water column.
07/12 Version 3.1
Page 11