HE-2000 Standard_e
23
Second step:
Twist the tool around and complete the insertion.
Place the prepared cable into the appropriate Fiberholder and
proceed with the stripping and splicing procedure as described
on section cable preparation once finished continue the
procedure as described on section channel connector.
To conclude short the Kevlar about 5mm and put the crimping
ring (30) into the right position, by using the crimping pliers
(1056892) crimp the sleeve in three steps with Hexagon slot
1-2 and 3.
At this point your ferrules should look like this.
Repeat sequence for all 4 ferrules.
Insert the nut (10) the ring (70) the metal washer (20) and
rubber washer (30) over the terminis.
4
Cable preparation