HE-2000 Standard_e
27
MEASUREMENT METHOD IL
21.
Measurement fanout and patchcords MIL
Measurement method for MIL 38999 and HE-2000 components
21.1
Measurement instruments
21.1.1
Light source
Components SM:
Components MM:
Light source Laser or LED
Light source LED
21.1.2
Mode Filter
Components SM:
Components MM:
Not defined (the ca. 3 m fiber of the reference patchcord is sufficient)
‘Mode conditioner’ already present at the MM measurement station
21.1.3
Receiver (Power Meter)
Set wavelength as light source.
21.1.4
Wavelength
Components SM:
1310 nm and/or 1550 nm
Components MM: 850 nm and/or 1310 nm
21.1.5
Reference patchcords
Use the reference patchcords as indicated in paragraph 6. For so called reference
connectors and bulkheads MIL 38999 / HE-2000, see details in paragraph 21.1.6.
21.1.6
Technical abbreviations and symbols
Abbreviations
Symbols
Definitions
Reference connector MIL 38999 / HE-2000
1)
REF
DUT
Connectors MIL 38999 / HE-2000 under test
Reference Bulkhead MIL 38999 / HE-2000
1)
REF
DUT
Bulkhead MIL 38999 / HE-2000 under test
Generic connector on reference fanout
2)
REF
DUT
Generic connector on fanout under test
1)
The so-called MIL 38999 / HE-2000 reference connectors and
bulkheads on fanout are to be assembled in the best possible way
and stored as reference patchcords.
IReference connectors on the exit side of the fanout, mentioned
in point 1) are to be assembled as 0.1 dB. This way the
attenuation caused by the above mentioned will be reduced to the
minimum.
2)
5. MEASUREMENT METHOD IL
5
Measurement Method IL