Defrosting 

 
UR-models defrosts automatically when the compressor stops. 
 
UF-models must be defrosted manually. We recommend defrosting the freezer every three month or 
if the layer of ice exceeds 5 mm. 
  
Do never use metal or other sharp objects to scrape the internal sides as it can damage the freezer 
 

1.

 

Disconnect the freezer 

2.

 

Empty the freezer 

3.

 

Leave the freezer with the door open 

4.

 

Place a tray in the bottom of the cabinet to collect defrosted water. 

5.

 

Clean the freezer with mild detergent and wipe thoroughly 

6.

 

Connect the freezer and it is ready for use.

 

  

 

Lock 
 

The freezer is supplied with a lock in the control panel. 
 

 

 
 

Maintenance and cleaning 

 
Switch the cooler off at the socket.  
 
The cabinet must be periodically cleaned. Clean the external and internal surfaces of the cabinet 
with a light soap solution and subsequently wipe dry. External surfaces can be maintained using 
steel oil.   
 
Do NOT use cleansers containing chlorine or other harsh cleansers, as these can damage the 
stainless steel surfaces and the internal cooling system. 
 
Clean the condenser and the compressor compartment using a vacuum cleaner and a stiff brush.  
 
Do NOT hose the compressor compartment with water as this can cause short circuits and damage 
on the electrical parts.  
 

 
 
 
 
 
 

Summary of Contents for N600

Page 1: ...Mod N600 Production code UF600 11 2010 ...

Page 2: ...Model UR200 UR400 UR600 UF200 UF400 UF600 Users manual UK ...

Page 3: ...inner gasoline etc in the cabinet 8 We declare that no asbestos nor any CFC are used in the construction 9 The oil in the compressor does not contain PCB Unpacking and installation Remove the wooden pallet and the packing External surfaces are supplied with a protection foil which must be removed before installation To ensure correct function it is important that the cabinet is level The cabinet i...

Page 4: ... three cores for use with a 3 pin 13 Amp or 3 pin 15 Amp plug If a B S 1363 13 Amp fused plug is used it should be fitted with a 13 Amp fuse The wires in this mains lead are coloured in accordance with the following code Green Yellow Earth Blue Neutral Brown Live The main electrical connections must be done by skilled electricians Start up of the cabinet Before use we recommend that the cabinet is...

Page 5: ...continuously for more than 3 seconds and the display shows the set temperature Press this key to increase the set temperature Press this key to lower the set temperature Press this key to save the new settings The display will flash with the new value and will then return to normal reading Alarm codes P1 Flashing in the display indicates that the cabinet sensor is defective The cabinet will strive...

Page 6: ...ct the freezer and it is ready for use Lock The freezer is supplied with a lock in the control panel Maintenance and cleaning Switch the cooler off at the socket The cabinet must be periodically cleaned Clean the external and internal surfaces of the cabinet with a light soap solution and subsequently wipe dry External surfaces can be maintained using steel oil Do NOT use cleansers containing chlo...

Page 7: ...ilure of the cabinet please contact your supplier Please inform model and serial number of the cabinet You can find this information on the rating label which is placed inside the cabinet in the top right hand side Disposal Disposal of the cabinet must take place in an environmentally correct way Please note existing regulation on disposal There may be special requirements and conditions which mus...

Reviews: