Operator's guide
7. FILLING AND EMPTYING THE BASIN
1.
2
3.
8. CONNECTION TO THE MAINS
1
(A)
2
3
4.
5
9. CONTROLS
1. Thermostat:
2. Basin resistor switch:
3. Heating
lamp switch:
4. Energy-regulator:
5. Cover lifting switch:
6. Light switch:
7. Water level alarm:
10. CHECKING CORRECT OPERATION
Make sure that: 1.
2
3
4
5
6.
7
8.
The basin must be filled manually, taking care not to fill above the level indicated on the basin walls.
. The machine gives an acoustic warning signal to advise you when water must be added to the basin.
To empty the basin, open the tap fitted on one of the machine's sides.
. Ensure that mains voltage and frequency are the same as those stated on the rating plate
attached
to the appliance. . Ensure that the supply socket:
. Ensure that there is no danger of explosion (AD) in the
room.
Make sure the environment is suitable for the power supply cable provided. The cable of the
appliance is H05 VVF, designed for internal use. For installation in other than internal settings, it will be
necessary to replace the cable with the appropriate type (for example H07 VVF for external settings).
. Insert the plug in the socket. The machine is not supplied with a plug. Provide the power supply cable
with a plug fulfilling the power requirements indicated on the rating plate (do not use three-way adapters
and reduction adapters) (see fig. 6).
The appliance features controls situated in a protected panel.
to adjust the temperature in
the appliance.
to switch on the resistors of the bain-marie basin.
to switch on the heating lamps.
to adjust the intensity of the heating
lamps.
to open and close the cover - Position II to lift - Position O to stop -
Position I to lower.
to turn on the internal light.
signalling when
water must be added (see fig. 7).
the plug is connected; . cover is open;
. bain-marie resistor switch is on (green
light lit up); . heating lamps are on; . water level in the bain-marie basin is within the limits.
Remove
any obstructions in front of the float hole. . Check that the set temperature is correct.
Keep the
machine away from inflammable material or any danger of explosion.
a)
b)
c)
is properly earthed;
fulfils the requirements of the
rated current as set out on the rating plate;
complies with the IEC regulations:- differential thermal-
magnetic switch (also known as ground fault interrupter) with In = rated value as stated on the rating
plate; - differential with Id sensitivity = 30 mA.