background image

For self-testing

TD-4289B

 

TaiDoc Technology Corporation

 

Bi.7F,No.127,Wugong 2nd Rd.,

 

Wugu Dist., 24888 New Taipei City, Taiwan

 

MedNet EC-REP GmbH

 

Borkstraße 10, 48163 Münster, Germany 

Import Europa: HT Medical BV

 

Distributor: GD Medical Pharma BV

Hastelweg 224, 5652 CL Eindhoven

info@gdmedicalpharma.nl

The Bluetooth® word mark and logos are registered trademarks 

owned by Bluetooth SIG, Inc. and any use of such marks by HT Medical BV 

is under license.Other trademarks and trade names are those of their 

respective owners.

Summary of Contents for XPER TD-4289B

Page 1: ...BLOOD GLUCOSE KETONES MONITORING SYSTEM USER MANUAL TD 4289B Version 1 02018 10 DT091018 01F Blood glucose Ketones ...

Page 2: ...o easily measure your own levels wherever and whenever you want Should you have any further queries after reading this manual please contact customer support or your distributor Use This system is intended for exterior use in vitro diagnostic use in a non clinical environment by persons with diabetes and in a clinical environment by healthcare processionals as an aid for assessing the effectivity ...

Page 3: ...tion 7 Meter overview 8 Display 9 Test strip 9 SETTING UP THE METER 10 SETUP MODE 11 For blood sugar testing 11 For β ketone testing 11 QUALITY CONTROLTEST 11 When should you test the device using control solution 11 Performing a test with the control solution 11 TESTING USING BLOOD SAMPLES 12 Preparingthelancingdeviceforabloodtest 12 Preparing the puncture point 12 Performing a blood sugar test 1...

Page 4: ... to receive results that are lower or higher than normal then contact your healthcare professional and follow their advice Only use fresh whole blood samples for testing your blood sugar and β ketone levels Using any other substances will produce incorrect results If you are displaying symptoms that do not match the test results and if you have followed all the instructions in this manual then ple...

Page 5: ... Gen at any time AC before meals PC after meals Automatic quality control mode QC Quality control test using the control solution Average over a number of days Memory symbol Date Time Error warning Alarm symbol Measurement unit Ketone symbol Absorbent opening Test strip grip PLEASE NOTE The front of the test strip must be facing upwards when you insert the test strip The test results could be inco...

Page 6: ...th the control solution when first using the Diatesse XPER When you think that either the meter or the test strips are defective When your test results do not match the way you are feeling or when you believe the results are not accurate When performing a test If you have dropped the meter or have reason to believe it is damaged When the hour minute are flashing press M to select the desired hour ...

Page 7: ...drop must be at least as large as actual size which equals around 0 5 microliter µI volume for a blood sugar test and 0 8 microliter µl volume for a β ketone test Carefully squeeze the area around the puncture point to draw a further blood drop Take care NOT to smear out the blood sample 4 Apply the sample to the test strip j Carefully allow the test strip to come into contact with the blood drop ...

Page 8: ...se contact your local customer support or distributor for assistance 1 Installing the software The software can be downloaded from the website www diatesse nl 2 Connecting the meter to a computer using a USB cable or optionally wirelessly using Bluetooth Windows 10 and up USB cable Insert the cable in an unused USB port on your computer Insert the other end of the cable in the meter s data port wh...

Page 9: ...g The meter will warn you in one of the following ways when the power is low 1 The symbol appears together with notifications on the display the meter is working and the results are still accurate but the batteries must be replaced 2 The symbol appears together with E b Error and LOW There is not enough power to perform a test The batteries must be replaced immediately Replacing the batteries The ...

Page 10: ...d between 10 and 85 relative humidity non condensing for β ketone test strips DO NOT freeze Keep the tests strips in their original tube Do not place in a different tube For foil wrapped test strips do not unwrap until required Store the packaging containing the test strips in a cool and dry place Keep away from direct sunlight and heat Reseal the tube immediately after removing a blood sugar test...

Page 11: ...0 6 mmol L 1 The βOHB concentration can increase if you are fasting and or dieting exercising intensively or suffer from diabetes and fall ill If your β ketone test results in a Lo repeat the test using a new test strip If you receive the same result or if the result does not match how you are feeling then contact your healthcare professional Always follow the recommendations of your healthcare pr...

Page 12: ...ters Check that the code chip has been correctly inserted Check that the code chip used supports the parameters of your meter MESSAGE WHAT IT MEANS WHATTO DO Batteries are dead Insufficient blood sample Test performed incorrectly The control solution bottle was not shaken properly The control solution has expired or is contaminated The control solution is too hot or cold Defective test strip Meter...

Page 13: ...ntdown Automatic switch off after 3 minutes of inactivity Temperature warning Operating conditions Blood sugar 8 C to 45 C 46 4 F to 113 F and 10 to 90 relative humidity non condensing β ketones 10 C to 40 C 50 F to 104 F and 10 to 85 relative humidity non condensing Storage transport conditions for the meter 20 C to 60 C 4 F to 140 F between 10 and 93 relative humidity non condensing Storage tran...

Page 14: ...26 27 NOTES ...

Page 15: ... Borkstraße 10 48163 Münster Germany Import Europa HTMedical BV Distributor GD Medical Pharma BV Hastelweg 224 5652 CLEindhoven info gdmedicalpharma nl TheBluetooth wordmarkandlogosareregisteredtrademarks ownedbyBluetoothSIG Inc andanyuseof suchmarksbyHTMedicalBV isunderlicense Othertrademarksandtradenamesarethoseof their respectiveowners ...

Reviews: