•  ONLY use the meter for the purposes set 

  out in this manual.

•  Do not use ANY accessories not specified 

  by the manufacturer.

• Do NOT use the meter if it is 

  malfunctioning or damaged.

•  This meter is not designed to cure given 

  symptoms or diseases. The measured 

  data serve solely as reference values. 

  Always consult your diabetes physician 

  and/or GP for the proper interpretation of 

  the results you have measured.

•  Read all the instructions carefully and 

  practice the procedure a number of times 

  before actually testing your blood sugar 

  and/or ketone levels. Perform all quality 

  checks in accordance with the instructions.

•  Keep the meter and all its parts out of 

  reach of young children. Small parts, such 

  as the battery cover, the batteries, test 

  strips, lancets and caps are a potential 

  choking hazard.

•  Use the meter in a dry environment, 

  especially if synthetic materials are 

  present (such as synthetic clothing or 

  carpeting), which can cause a static charge 

  that could mean incorrect results. 

BEFORE YOU START

 ...................................

7

Important information ................................ 7

Meter overview ........................................... 8

Display......................................................... 9

Test strip ...................................................... 9

SETTING UP THE METER

 ..........................

10

SETUP MODE

 ............................................

11

For blood sugar testing .............................11

For 

β

-ketone testing ..................................11

QUALITY CONTROL TEST

 ..........................

11

When should you test the device using 

control solution? .......................................11 

Performing a test with the control solution ..11

TESTING USING BLOOD SAMPLES

 .........

12

Preparing the lancing device for a blood test ..12

Preparing the puncture point ...................12

Performing a blood sugar test ..................13

METER MEMORY

 .....................................

14

Viewing the test results .............................14

Viewing the average of blood sugar results 

over a number of days ..............................15

DOWNLOADING YOUR RESULTS  

TO A COMPUTER

 ......................................15

CONNECTING THE METER TO  

A SMARTPHONE

 ......................................

16

Maintenance .............................................17

Battery .......................................................17

Replacing the batteries .............................17

Caring for your meter ................................18

Caring for your test strips ..........................19

Important information on the  

control solution .........................................19

READING THE RESULTS

  ..........................

20

For blood sugar tests .................................20

For 

β

-ketone tests ......................................20 

• Do NOT use the meter near sources of 

  strong electromagnetic currents, as the 

  accuracy of the measurement could be 

 affected.

•  Proper maintenance is essential to 

  the operating life of your meter. If you 

  are worried about the accuracy of your 

  measurements, contact customer support 

  or your distributor for support.

REFERENCE VALUES

 ................................

21

For blood sugar tests .................................21

For 

β

-ketone tests ......................................21

TROUBLESHOOTING SYSTEM ISSUES

 ....

22

Error messages ..........................................22

Troubleshooting ........................................23

INFORMATION ON SYMBOLS

 .................

24

SPECIFICATIONS

 ......................................

25

4

5

Summary of Contents for XPER TD-4289B

Page 1: ...BLOOD GLUCOSE KETONES MONITORING SYSTEM USER MANUAL TD 4289B Version 1 02018 10 DT091018 01F Blood glucose Ketones ...

Page 2: ...o easily measure your own levels wherever and whenever you want Should you have any further queries after reading this manual please contact customer support or your distributor Use This system is intended for exterior use in vitro diagnostic use in a non clinical environment by persons with diabetes and in a clinical environment by healthcare processionals as an aid for assessing the effectivity ...

Page 3: ...tion 7 Meter overview 8 Display 9 Test strip 9 SETTING UP THE METER 10 SETUP MODE 11 For blood sugar testing 11 For β ketone testing 11 QUALITY CONTROLTEST 11 When should you test the device using control solution 11 Performing a test with the control solution 11 TESTING USING BLOOD SAMPLES 12 Preparingthelancingdeviceforabloodtest 12 Preparing the puncture point 12 Performing a blood sugar test 1...

Page 4: ... to receive results that are lower or higher than normal then contact your healthcare professional and follow their advice Only use fresh whole blood samples for testing your blood sugar and β ketone levels Using any other substances will produce incorrect results If you are displaying symptoms that do not match the test results and if you have followed all the instructions in this manual then ple...

Page 5: ... Gen at any time AC before meals PC after meals Automatic quality control mode QC Quality control test using the control solution Average over a number of days Memory symbol Date Time Error warning Alarm symbol Measurement unit Ketone symbol Absorbent opening Test strip grip PLEASE NOTE The front of the test strip must be facing upwards when you insert the test strip The test results could be inco...

Page 6: ...th the control solution when first using the Diatesse XPER When you think that either the meter or the test strips are defective When your test results do not match the way you are feeling or when you believe the results are not accurate When performing a test If you have dropped the meter or have reason to believe it is damaged When the hour minute are flashing press M to select the desired hour ...

Page 7: ...drop must be at least as large as actual size which equals around 0 5 microliter µI volume for a blood sugar test and 0 8 microliter µl volume for a β ketone test Carefully squeeze the area around the puncture point to draw a further blood drop Take care NOT to smear out the blood sample 4 Apply the sample to the test strip j Carefully allow the test strip to come into contact with the blood drop ...

Page 8: ...se contact your local customer support or distributor for assistance 1 Installing the software The software can be downloaded from the website www diatesse nl 2 Connecting the meter to a computer using a USB cable or optionally wirelessly using Bluetooth Windows 10 and up USB cable Insert the cable in an unused USB port on your computer Insert the other end of the cable in the meter s data port wh...

Page 9: ...g The meter will warn you in one of the following ways when the power is low 1 The symbol appears together with notifications on the display the meter is working and the results are still accurate but the batteries must be replaced 2 The symbol appears together with E b Error and LOW There is not enough power to perform a test The batteries must be replaced immediately Replacing the batteries The ...

Page 10: ...d between 10 and 85 relative humidity non condensing for β ketone test strips DO NOT freeze Keep the tests strips in their original tube Do not place in a different tube For foil wrapped test strips do not unwrap until required Store the packaging containing the test strips in a cool and dry place Keep away from direct sunlight and heat Reseal the tube immediately after removing a blood sugar test...

Page 11: ...0 6 mmol L 1 The βOHB concentration can increase if you are fasting and or dieting exercising intensively or suffer from diabetes and fall ill If your β ketone test results in a Lo repeat the test using a new test strip If you receive the same result or if the result does not match how you are feeling then contact your healthcare professional Always follow the recommendations of your healthcare pr...

Page 12: ...ters Check that the code chip has been correctly inserted Check that the code chip used supports the parameters of your meter MESSAGE WHAT IT MEANS WHATTO DO Batteries are dead Insufficient blood sample Test performed incorrectly The control solution bottle was not shaken properly The control solution has expired or is contaminated The control solution is too hot or cold Defective test strip Meter...

Page 13: ...ntdown Automatic switch off after 3 minutes of inactivity Temperature warning Operating conditions Blood sugar 8 C to 45 C 46 4 F to 113 F and 10 to 90 relative humidity non condensing β ketones 10 C to 40 C 50 F to 104 F and 10 to 85 relative humidity non condensing Storage transport conditions for the meter 20 C to 60 C 4 F to 140 F between 10 and 93 relative humidity non condensing Storage tran...

Page 14: ...26 27 NOTES ...

Page 15: ... Borkstraße 10 48163 Münster Germany Import Europa HTMedical BV Distributor GD Medical Pharma BV Hastelweg 224 5652 CLEindhoven info gdmedicalpharma nl TheBluetooth wordmarkandlogosareregisteredtrademarks ownedbyBluetoothSIG Inc andanyuseof suchmarksbyHTMedicalBV isunderlicense Othertrademarksandtradenamesarethoseof their respectiveowners ...