background image

Centrifugal in-line electric fan

CYCLONE-EBM

Passport

Service instruction

EN

Assignment

Centrifugal in-line electric fan CYCLONE – EBM  is intended for 

application in rooms of residential and public buildings, and also in 
auxiliary buildings of the industrial enterprises.

Technical characteristics

CYCLONE – EBM  fan is issued six standard sizes depending on the install 

housing diameter.

Notation:

CYCLONE-EBM 100

CYCLONE-EBM 125

CYCLONE-EBM 160

CYCLONE-EBM 200

CYCLONE-EBM 250

CYCLONE-EBM 315

Fan look, basic dimensions, connecting sizes and technical characteristics 

described in pic.1 and lists of dimensions and characteristics.

C

30

30

ØD

ØD

ØB

Pictu

re

1

“ERA” fans are manufactured according to specs 4861-006-96059883-

2014, valid rules and standards. Fans are intended for alternate current 

network connection of 220-240 V voltage and 50 Hz frequency. 

Safety requirements

Base on type of protection from electric shock the fans relate to the class I 

devices per GOST(all-union State Standard) 12.2.007.0-75. The level of fan 

protection against dangerous parts and water is IP X4. The level of motor 

protection against dangerous parts and water is IP 44.

Attention!

Fan operation outside the specified temperature range (from -25C 

to +70C) is prohibited.

 

It is prohibited to install fan in the same air vent line together with 

smoke emission pipe of the fuel burner devices.

Type

Dimensions, mm

D

B

C

CYCLONE-EBM 100

99

251

215

CYCLONE-EBM 125

124

251

220

CYCLONE-EBM 160

159

340

229

CYCLONE-EBM 200

199

339

250

CYCLONE-EBM 250

249

339

250

CYCLONE-EBM 315

314

405

284

Characteristics

100

125

160

200

250

315

Power consumption (W)

52

52

85

135

210

225

Fan efficiency (m

3

/hour)

265

370

680

900

1100

1700

Frequency of rotation, r.p.m.

2350

2350

2700

2650

2500

2700

Pressure, Pa

310

310

400

540

580

740

Noise amount (dB)

52

51

57

55

53

53

The set of delivery

•  Assembled fan

•  Passport/instruction
•  Packing box

Maintenance

•  switch off the fan; 

•  disconnect it from air ducts and air dispensers and remove from the 

installation site; 

•  remove dust from blades of the driving wheel, using a soft dry brush 

or cloth;

•  clean blades of the driving wheel, using soapy water;

•  wipe all plastic parts with a soft cloth dampened with soapy water; 

•  wipe all surfaces dry; 

•  assemble and install the fan in place;

•  recommended to do the cleaning 1 time in 6 months.

Attention!

Do not allow the cleaning solution to the motor!

Storage and transportation

Keep the fan only in  manufacturer packaging in a ventilated room with 

temperature range from -40°C to +80 ° C and relative humidity of 80% (at T = 

25 ° C). Shelf life - 5 years from manufacture date.

 Products are to be transported by any transport, provided that manufacturer 

packaging is safe from direct exposure to rainfall, impact from other products, 

displacement during transportation. Transportation is conducted, according 

to the rules applicable for this transport.

Reviews: