OPERATOR’S MANUAL
Control Point
®
11001-1489-201702 Rev B
SYSTEM CALIBRATION / 77
5. Repeat this procedure for the remaining control channels. Multiple runs
and averaging results are unnecessary. Liquid must be primed before
running a system response. The UNLOAD feature can be used to
prime the pump.
FINE TUNING SYSTEM RESPONSE CONSTANTS
The Automatic System Response routines are not necessarily exact.
Operators may want the system to respond faster or slower than calculated
by the automatic routines. These values can be adjusted slightly to tailor the
response to operator needs.
IMPORTANT: Automatic routines must always be run prior to
modification to establish basic values. The following are
a few general guidelines.
Figure 47
Proportional Valve Spinner Calibration Screens
SYS RSPNS CONSTANT
If the control system responds slowly to changes in speed and is slow to
start, the SYS RSPNS value should be increased. If the system is
oscillating around the target APR, the SYS RSPNS may be too large and
should be decreased. Excessive oscillation should be limited to ±5% of the
target APR to minimize wear on the PWM valve. Most systems can be
tuned by altering only this value.
SPINNER CONFIGURATION
UNLOAD
NO
NO GND SPD
NO
DRV FREQ
100
HZ
PULSE FDBK
NO
GSRS SLPE
0.0
RPM/MPH
MAX GSRS
0
MPH
BLAST RATE
0
%
SYS RSPNS
10.0
VALV BOOST
2.5
MORE . . .
SPINNER CONFIGURATION
MORE . . .
AFILT
0.250000
PWM OFFSET
15
PWM SAT
100
GSRS ENABLE
YES
Press Function Key F8
(SPINNER)
(No Function screen appears)
• PWM SAT and SPRD LIMIT appears only
for proportional valve
Summary of Contents for Control Point
Page 1: ...CONTROL POINT CONTROL SYSTEM Operator s Manual SINCE 1966 ...
Page 5: ...OPERATOR S MANUAL Control Point 11001 1489 201702 Rev B IV ...
Page 7: ...OPERATOR S MANUAL Control Point 11001 1489 201702 Rev B 2 SAFETY NOTICES ...
Page 13: ...OPERATOR S MANUAL Control Point 11001 1489 201702 Rev B 8 INTRODUCTION ...
Page 29: ...OPERATOR S MANUAL Control Point 11001 1489 201702 Rev B 24 START UP AND FAMILIARIZATION ...
Page 77: ...OPERATOR S MANUAL Control Point 11001 1489 201702 Rev B 72 KEYBOARD PROGRAMMING ...
Page 79: ...OPERATOR S MANUAL Control Point 11001 1489 201702 Rev B 74 SYSTEM CALIBRATION ...
Page 91: ...OPERATOR S MANUAL Control Point 11001 1489 201702 Rev B 86 SYSTEM CALIBRATION ...