Keypad Operation

On/Off

When you press the “ON/OFF” key the pens will 
move to the correct reading.

Alarm Set

The alarm set keys are labeled with arrows that 
point up and down. You can set a minimum and 
maximum alarm for both of the two variables you 
are recording.
  1.  To set the alarms press the “ALARM SET” key.  
    The MIN symbol will be displayed and the  
    temperature will flash. (Note: The alarm set  
    function always starts with temperature. If 
    you do not want an alarm to sound for 
    temperature readings set the alarms for points  
    that are outside of the range.)
  2.  Use the up arrow button to increase the 
    minimum temperature alarm setting and the  
    down arrow to decrease the minimum 
    temperature alarm setting.
  3.  Press “ALARM SET” key a second time. The 
    MAX symbol will appear and the temperature  
    will flash indicating that you can now set the  
    maximum temperature alarm. Use the same  
    procedure as in step 2 above for setting the  
    temperature maximum alarm setting.
  4.  Press the “ALARM SET” key a third time and  
    the MIN symbol will appear and humidity  
    (or dew point dip switch #5 is on) will flash.  
    Use the same process as in steps 2 and 3  
    above to set humidity and dew point alarm.
  5.  When you have set alarms for both variables  
    press “ALARM SET” a final time to lock in 
    settings.

The defaults for alarm settings are:
  Temperature: +40°F min to +110°F max
  Humidity: 20% min, 80% max

NOTE: Alarm settings will return to the default when 
AC power fails and there are no batteries installed 
for back-up power.

Alarm ON/OFF

This button turns the alarms on and off. When 
alarms are “ON” the alarm symbol appears on the 
display. When alarm sounds it will sound audibly for 
approximately 1 minute and then it will stop. For a 
visual, the variable that has moved outside of the 
minimum or maximum points that you set will flash 
(i.e. if you set a maximum alarm for +80°F and tem-
perature r80°F the temperature portion of 
the display will flash).

MIN/MAX

  1.  Press the “MIN/MAX” key once and the    
    minimum values, during the recording time,  
    will be displayed for 7 seconds.
  2.  Press the “MIN/MAX” key again and the 
    maximum values, during the recording time,  
    will be displayed for 7 seconds.
  3.  Press the “MIN/MAX” key a third time during  
    this period and the display will show current  
    readings. The unit will always return to current 
    readings mode after 7 seconds.

NOTE: Turning the unit off resets the minimum and 
maximum values.

Pen Home

Press the “PEN HOME” key while the unit is operat-
ing and the pens move to the outside of the chart. 
Press the “PEN HOME” key again and the pens will 
return to current reading points on the chart.

Display Change

Press the “DISPLAY CHANGE” key and the display 
will temporarily show the reading opposite of what 
is being recorded (i.e. if dip switch #5 is off and 
you are recording the RH, pressing the “DISPLAY 
CHANGE” key will temporarily change the display to 
show the dew point reading).

NOTE: If the unit does not respond to keypad, check 
to see that dip switch #8 is off.

ON/OFF

MIN/MAX

DISPLAY

CHANGE

PEN

HOME

ALARM

SET

ALARM

ON/OFF

Figure 3

Summary of Contents for THDx

Page 1: ... Operation Dip Switch Setup Warranty Troubleshooting Factory Service Returns Order Form Product Specifications Features Operating Information Display Symbols Charts Accessories Calibration Instrument Anatomy Getting Started Installation Keypad Operation Dip Switch Setup Warranty Troubleshooting Factory Service Returns DICKSON DICKSON 930 South Westwood Avenue Addison Illinois 60101 Phone 630 543 3...

Page 2: ...se Time 2 5 min for 63 of full scale NOTE Response time is slower when using battery Calibration User calibration of all variables Product Features Remote sensing capability with optional extension cords 10 50 and 100 available see Accessories Alarms Audio Visual with High Low setting capabilities Microprocessor control and electronic sensing C F and RH Dew Point switchable Large 8 diameter circul...

Page 3: ...he unit upside down or on its side so that you can see where the probe connects to the back of THDx 2 Twist and pull the black rubber strain relief beginning on the back of the recorder body see Instrument Anatomy 3 Slide the strain relief on the cord 4 Inside you will see a standard connector which looks like a phone jack Using a small screw driver press retention tab and the connector will pop o...

Page 4: ...tch 5 to select humidity or dew point RH 5 off Dew Point 5 on Use dip switch 3 to select F or C F 3 off C 3 on 2 To activate the calibration mode turn the unit off Now press the On Off key and the up arrow key at the same time The UC symbol will appear in the display to indicate you are in User Calibration mode 3 Place the probe of the unit along with your precision relative humidity dew point ins...

Page 5: ...tomy Getting Started Installation Keypad Operation Dip Switch Setup Warranty Troubleshooting Factory Service Returns DICKSON Instrument Anatomy Figure 1 Figure 2 Alarm Sound Source AC Adapter Jack Strain Relief Probe Pen Lifting Bar Chart Hub Timing Clip Temperature Pen Humidity Dew Point Pen Pen Cap Holders Chart Guide Clip ...

Page 6: ... chart should lay flat on the dial face into the groove in the chart hub and turning clockwise until the correct hour and day on the chart is referenced to the timing clip see Instrument Anatomy if you need assistance locating instrument parts 3 Remove the protective pen caps 4 Press the On Off key and the pens will move to the current reading After you get started using the Quick Start Instructio...

Page 7: ... settings are Temperature 40 F min to 110 F max Humidity 20 min 80 max NOTE Alarm settings will return to the default when AC power fails and there are no batteries installed for back up power Alarm ON OFF This button turns the alarms on and off When alarms are ON the alarm symbol appears on the display When alarm sounds it will sound audibly for approximately 1 minute and then it will stop For a ...

Page 8: ...s four different recording time options 1 day 7 day 14 day and 31 day Dip Switch 1 and 2 control the recording time 7 day 1 off 2 off 1 day 1 off 2 on 14 day 1 on 2 off 31 day 1 on 2 on NOTE Remember to install correct chart to match corresponding switch setting F C You can record in F or C with the THDx by using dip switch 3 F 3 off C 3 on Temperature Range The THDx will record in two temperature...

Page 9: ...Check both dip switch 7 8 Both should be off to allow operation Pen trace too fine or absent Pen may need to be replaced moistened or sanded Remove pen cap Display shows Err Temperature being monitored is too high see pg 2 Display shows Prob Temperature being monitored is extremely cold or probe is disconnected Display shows cold Temperature being monitored is too low see pg 2 Display shows frozen...

Page 10: ...ice Unit Total each each each each Subtotal In Illinois add 7 5 sales tax 4 Tax Freight All Prices in U S Dollars 4 Total Step 4 Payment Method Check Check Money Order Credit Card Credit Card Number Expires mm yy Signature Purchase Order P O Net 15 days for established customers Customer U S A Freight Charges Fax to 1 800 676 0498 Mail to Dickson 930 S Westwood Ave Addison IL 60101 Total Order UPS...