Dickson KT6P Manual V3 

 
 

 

Replaceable Sensor Certificate of Validation 

 

Dickson ensures that the Replaceable Sensors / Instruments listed below were developed, tested 

and validated together. 
 

Replaceable Sensor Model: R400 

 

Instrument Model: KT6P1, KT6P2, KT6P5  

 
Operation:  The Instruments and Replaceable Sensor models listed above were specifically 

designed to work together.  No other sensors will work with the Instrument models listed.  No 
other Instrument will work with the Replaceable Sensors listed.  The Replaceable Sensor must be 
connected to the Instrument for the Instrument to operate properly. 

 
Calibration:  Only the Replaceable Sensor is calibrated.  The sensor, and all calibration defaults 
and adjustments are stored on the Replaceable Sensor.  Accuracy is strictly controlled by the 

sensor – no adjustments are made by the Instrument.  Readings are sent from the Replaceable 
Sensor to the Instrument for storage purposes only.  Certificates of Calibration / NISTs are only 
supplied for the Replaceable Sensor for this reason.   

 
Recalibration:  When a Replaceable Sensor is due for recalibration the existing Replaceable Sensor 
can be replaced with a new Replaceable Sensor thus eliminating the need to return the entire 
instrument for recalibration.  Replaceable Sensors can be returned for recalibration as well. 

 

www.

.com

information@itm.com

1.800.561.8187

Summary of Contents for KT6P1

Page 1: ...he timing arrow just to the right of the pen tip on the dial Press Pen Home to move the pen s back onto the chart The following feature should be used for fine adjustments only b To adjust the chart t...

Page 2: ...set the alarm make sure unit is on and press and hold the Alarm button The LED will blink red rapidly for about five seconds then the LED will turn solid green Release the Alarm button and the LED wi...

Page 3: ...ill close on alarm conditions when the alarms are enabled Relay contacts are always functional when the alarm is enabled The relay will close only during minimum and maximum alarm conditions Relays wi...

Page 4: ...d green Release the Pen Home and On Off buttons The LED will flash amber and green for one second then the LED will turn off Note Press Pen Home first so the unit will not turn off 2 The pen will move...

Page 5: ...tion If you wish to cancel the Calibration simply enter Calibration mode and toggle through the steps without adjusting displayed readings Exit by pressing the On Off button You have now restored fact...

Page 6: ...d enough time to recognize this and switch to battery mode The Chart Recorder may lock up or shut off in this situation This situation may also occur if the unit is plugged into an outlet that shares...

Page 7: ...t to operate properly Calibration Only the Replaceable Sensor is calibrated The sensor and all calibration defaults and adjustments are stored on the Replaceable Sensor Accuracy is strictly controlled...

Reviews: