    Remote Sensing

Remote Sensing

Remote Sensing

Remote Sensing    Temperature

Temperature

Temperature

Temperature/Humidity 

/Humidity 

/Humidity 

/Humidity Recorder

Recorder

Recorder

Recorder    

GETTING STARTED

GETTING STARTED

GETTING STARTED

GETTING STARTED    
7-day chart rotation 
0 to 100

o

F (TH6P3) 

+32 to 100F (TH6P1/2) 
 
QUICK START

QUICK START

QUICK START

QUICK START    

1.

1.

1.

1.

 

Remove the protective pen caps.   
 

2.

2.

2.

2.

 

Connect Sensor: TH6P1/2: Make sure the R200 replaceable sensor is connected firmly to 
the recorder.  TH6P3: Make sure the R250 sensor is connected firmly to the 10’ extension 
cable and the extension cable in plugged in firmly to the recorder.  

 

3.

3.

3.

3.

 

Insert 4AA batteries and plug in AC adapter (See Figure 3).  Unit will power on. 

 

4.

4.

4.

4.

 

The instrument will move pens to the appropriate readings. 

 

5.

5.

5.

5.

 

Install the chart that matches selected Dip Switch settings (See p.4). 
 
Press the PEN 

PEN 

PEN 

PEN HOME

HOME

HOME

HOME key to move the pens to the outside of the chart.  The pens are 

automatically raised off the chart. 
 
Remove the old chart, place the new chart on the Chart Hub being certain that the edge 
of the chart slides under the Chart Guide Clip located at the outside of the chart. 
 

6.

6.

6.

6.

 

Set the appropriate time.  There are two ways to adjust the chart and set the appropriate 
time: 

 

a.

 

Set the chart time manually by inserting a coin into the groove in the chart hub 
and turning clockwise until the correct hour (and day if applicable) on the chart is 
referenced to the timing arrow (just to the right of the pens tip on the dial).  Press 
Pen

Pen

Pen

Pen    Home

Home

Home

Home to move the pens back onto the chart. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

www.

.com

information@itm.com

1.800.561.8187

Summary of Contents for TH6P1

Page 1: ...rt 4AA batteries and plug in AC adapter See Figure 3 Unit will power on 4 4 4 4 The instrument will move pens to the appropriate readings 5 5 5 5 Install the chart that matches selected Dip Switch set...

Page 2: ...tions Keypad and Button Functions Keypad and Button Functions On Off On Off On Off On Off The On Off key turns the unit on and off Pen Pen Pen Pen Home Home Home Home If the pens are located on the ou...

Page 3: ...ve options until the A A A Alarm larm larm larm button is pressed to exit from alarm adjust Each press of the Pen Pen Pen Pen Home Home Home Home or Alarm Alarm Alarm Alarm button will store the new s...

Page 4: ...Home Pen Home Pen Home first so the unit will not turn off 2 Both pens will move to the outer edge of the chart and then the shorter red red red red pen will move to the outer chart ring maximum temp...

Page 5: ...complete press the On Off On Off On Off On Off button The adjustment is stored in memory even after you turn the unit off or if AC power fails Note Note Note Note After two hours if no buttons are pr...

Page 6: ...ck Why won t the battery back Why won t the battery back Why won t the battery back up work up work up work up work Are there good batteries in the Chart Recorder Keep in mind that battery backup vari...

Page 7: ...nsors will work with the Instrument models listed No other Instrument will work with the Replaceable Sensors listed The Replaceable Sensor must be connected to the Instrument for the Instrument to ope...

Reviews: