background image

Power Up

 and 

Power Down

05 Main Menu (Page 1)

Power Up increases the power to the Power-Limit value and then rolls over to 5W.
Power Down decreases the power down to 5W and then rolls over to the Power-Lim
value. The Power-Limit value is adjusted in the Extended Functions Sub-Menu “Heater”
and provides a protection feature for atomizers which are not prepared for high
wattage or to reduce the power range intentionally. The wattage step size is 1 Watt
below 20W, 2W between 20W and 40W and 5W above 40W, but can be set to 0.5W,
1W and 2.5W respectively in the modmenu with “Half Watt=1”.

With temperature controlled vaping activated, the power setting is the maximum
permitted power for the temperature regulator (do not mix this with “Power-Limit”).

In the operation mode “Bypass” (mechanical mod), the power setting is not available, because the power is
defined by the battery voltage and coil resistance. The menu items “Power Up/Down” are not displayed
in this case.

Temperature Up and Temperature Down

This Menu items are 

only available and displayed if temperature controlled vaping is

selected 

(see Heater-Control menu item below). So the menu structure adapts to the

selected operation mode. The Temperature Up/Down menu sets the setpoint for the coil
temperature during vaping. The temperature setpoint can be selected from 120°C to 
280°C (250°F- 540°F) in steps of 5°C (10°F). To achieve a high precision temperature control,
a correctly performed reference measurement (TempCal Init) is mandatory, see next item.

This is a display only menu item. The coil resistance is displayed in a range from
0.00 to 9.90 Ohms. If temperature controlled vaping is selected, the current measured
coil temperature is also displayed, if not, the display shows T ---.
If the display does not show 20°C even with cooled down atomizer, it is recommeded
to re-perform a manual calibration.

Coil Resistance and Coil Temperature

This Menu item is 

only displayed if temperature controlled vaping is selected 

(see

Heater Control menu item below). For the use of temperature controlled vaping, the
calibration measurement is a very important part of it. The Temperature calibration
measures the coil resistance at room temperature (20°C) as the reference for

Manual Coil Temperature Calibration

If the power level is smaller than the value needed to achieve the selected temperature, the operation
changes from a temperature regulator to a temperature limiter. Keep this in mind in case there is poor vape
and the display shows a smaller temperature than selected. If the power level is set sufficiently high, it adjusts
the heating up speed of the coil until the set-point temperature is reached. 

temperature controlled vaping. This, together with the wire’s temperature coefficient enables the mod to
calculate the coil’s temperature. The calibration must be confirmed in a second step to avoid accidential
activation. After confirmation the display shows “process” indicating that the calibration completed.
It is important to understand, that, if the calibration is performed at a temperature other than
20°C, the control will still regulate a constant temperature, but with an offset deviation.  So take the ambient
temperature during the temperature adjustment into account. E.g.doing the calibration at 40°C ambient, the
temperature should be set to 20°C less than normal. Similiar, if a wrong temperature coefficient was adjusted,
the actual temperature might deviate dramatically from the set-point (here it is a factor and not an offset).
Always perform a calibration, when a new atomizer is attached or when an atomizer is moved, e.g. when
turning it.

Summary of Contents for Dani 32.5

Page 1: ...manual Dani 32 5 ...

Page 2: ...Nickel Titanium appropriate stainless steel and others We recommend the dicodes resistance wire for optimal performance ease of use and unique liquid flavor 5 to 80W with one Li Ion battery Adjustable spring loaded high force 510 thread center pin made of CuBe Adjustable battery discharge level 2 5 3V Up to 12V output voltage Up to 22A output current Ultra low resistance CuBe Spring for contacting...

Page 3: ...Vaping Time Energy Joule Ws Battery Capacitance Reset Counters Total Lifetime Puffs Total Lifetime Vaping 03 Display Operation 1 1 1 not displayed in Bypass Mode 2 at low no current Ub0 and high current load UbL Temperature Calibration The MOD is equipped with a graphical OLED display which provides all important informations about the status during the vape and or for 4 seconds after each vape se...

Page 4: ...layed if not the display shows T If the display does not show 20 C even with cooled down atomizer it is recommeded to re perform a manual calibration Coil Resistance and Coil Temperature This Menu item is only displayed if temperature controlled vaping is selected see Heater Control menu item below For the use of temperature controlled vaping the calibration measurement is a very important part of...

Page 5: ... Or if the coil resistance is 0 1 Ohm the maximum power is 48 4W because 22A 0 1Ohm 48 4W As can be seen from the examples with high coil resistance the power is limited by the maximum output voltage of 12V and with low resistances by the maximum output current of 22A The fact is also reflected in the feature list A power of 80W is possible from 0 18 to 1 5 Ohms Nevertheless resistances of 0 05 to...

Page 6: ...Comment Boost 1 2 3 4 5 6 7 8 9 10 300 450 600 800 1000 120 160 200 250 300 700 800 900 1000 1000 ms Start Boost Start Boost Start Boost Start Boost Start Boost Periodic Boost Periodic Boost Periodic Boost Periodic Boost Periodic Boost Main Menu Extended Functions Heater Menu Extended Functions Heater Menü 05 Main Menu Page 3 Parameter We recommend to set the normal power not the boost to much low...

Page 7: ...ss the button Note After actively switching the device off it can be only switched on by five short clicks The Extended Functions Menu offers a lot of setting options of the mod to provide the highest possible flexibility for the user to individually adjust it to whatever preferences Normally once the settings were made the user will need to change the parameter rarely In order to keep the main me...

Page 8: ...y will create power losses in the batteries inner resistance as well as at all mechanical contacts which finally will reduce the total vape time and lead to volt drop To reduce the contact resistance from the battery bottom to the electronic tube the Dani 32 5 is equipped with an ultra low ohmic multi contact copper beryllium spring inside the battery cap This spring provides 8 contacts to the bat...

Page 9: ...s 2 but without animation visual shift effect setting 5 slowest as 4 but without fast auto repeat 1 The temperature coefficient selects the type of wire material range 50 to 650 When TC mode is selected Main menu HCtrl 1 the user must select the wire type to be NiFe30 dicodes wire Ni200 Titanium Stainless Steel SS316L Stainless Steel Inox or Other The value for Other is adjusted here The values of...

Page 10: ...arameter is used as the temperature coefficient The parameter can be found in the Extended functions menu Heater Menu TempCof The TempCof item in the menu is visible even if the operation mode selected is not temperature controlled vaping The selected voltage is the voltage at the input of the electronics when current is drained from the battery and includes any contact or other resistance voltage...

Page 11: ...th Expert Mode set to 1 are Power Boost Heater Protection and Bypass Here again the modes in an overview Standard Vaping with a constant power setting The selected power is applied to the coil unless the coil s resistance affords a different power setting Temperature The power applied to the coil is calculated by a temperature controller which keeps the Control coil s temperature constant Importan...

Page 12: ...ion of the batteries capacity Not counted are losses inside the battery contacts and electronic With this function the user can check whether the battery has about the capacity declared by the manufacturer the capacity available for vaping or whether the battery is wear out This counter can be reset to 0 TotCycl Total Cycles is the number of puffs throughout the entire mod s life It cannot be rese...

Page 13: ...er the malfunction is covered by the warranty please contact dicodes by email prior to sending back the device If a sent back defective device is not covered by the warranty dicodes will give the customer a quote for repair before any repair action takes place The postal fee or shipping charge from the customer to dicodes is not covered by the warranty in any case Please send the device to dicodes...

Page 14: ...ainst Nicotine Propylene Glycol and persons with cardiovascular disease Selling to persons below 18years of age prohibited Battery Disposal You bought a rechargable battery powered product The rechargable battery lasts long but wears out nevertheless Li Ion batteries may not be disposed in houshold waste Customers are obligated by law to dispose wear out batteries to apporiate gathering points Mod...

Reviews: