Yog’s E-PIPE one powered by dicodes
10
2. Heater Protection Mode (only when Expert Mode=1)
The Heater Protection mode causes a periodic interruption of the power supply. The
length and spacing of the interruptions is set via the "Heater Prot" parameter in the
Extended Functions menu. The repeated power interruption helps to avoid a breakdown
of the fluid flow and thus temperature rise.
The table below shows the shows the ratio of power-on to power-off time depending on
the parameter "Heater Prot":
Value Heater Prot
On-Time [ms]
Off-Time [ms]
Powerfactor
1
2
3
4
5
6
7
8
9
10
400
600
800
1000
1350
2000
2000
2000
2000
2000
100
100
110
120
150
200
180
150
100
80
0.80
0.86
0.88
0.89
0.90
0.91
0.92
0.93
0.95
0.96
3. Power Boost Mode (only when Expert Mode=1)
The Power Boost mode allows an initial short term high power pulse to be applied to the
coil (boost). In addition to 3 selectable initial boost lengths, further options generate a
periodic boost pulse of varying length and repetition rate. In addition to 3 selectable
initial boost lengths, other options generate a periodic boost pulse of varying length and
repetition rate. An initial boost is used to heat up the coil quickly.The periodic boost
allows the coil temperature to constantly exceed a certain range. In this case, different
flavors in the liquid, which all develop their flavor at different temperatures, are
addressed by the varying temperature.
We recommend setting the normal power (not the boost) to much lower values when
using the periodic boost, since the average power is increased by the boosts and the
temperature rises as a result.
Boost Power
Boost Time [ms]
time on nominal
power [ms]
effective power
(at 5W nominal power)
1
2
3
4
5
6
7
8
9
10
300
450
600
800
1000
100
150
200
250
300
-
-
-
-
-
700
800
900
1000
1000
start-boost
start-boost
start-boost
start-boost
start-boost
6.9
7.17
7.36
7.6
8.0
Note: If the set power value matches the power limit value, the power boost has no