Description
3.8
3.8
Technical Data
3.8.1
3.8.1
General installation conditions
3.8.1.1
3.8.1.1
Electrical characteristics of the supply network
Table 3-3:
Electrical characteristics
Electrical characteristics
Supply voltage range:
100 -120 V
220 - 240 V
Rated frequency:
50/60 Hz
50/60 Hz
Network Type:
TN network with PE conductor
TN network with PE conductor
Permissible tolerance for
rated voltage:
- 10% / + 6%
- 10% / + 6%
Permissible tolerance for
rated frequency:
±1%
±1%
3.8.1.2
3.8.1.2
System Requirements
100 - 120 V
220 - 240 V
Idle mode
Operation (max)
Idle mode
Operation (max)
Rated current consumption*:
1.0 A
6.5 A
0.5 A
3.5 A
Active power
105 W
700 W
105 W
700 W
Protection class:
I
I
Type of system connection
(wall outlet)
Country-specific safety plug
Country-specific safety plug
Fuse
20 A automatic circuit breaker
16 A automatic circuit breaker
*the rated current consumption depends on the configuration
Heating 1
(without system)
100 - 120 V
220 – 240 V
Rated current consumption:
4.5 A
2.5 A
Active power:
400 W
400 W
Copyright © 2021, Diebold Nixdorf
01750340329 E
3-25