• Keep the minimum distance from other
appliances and units.
• Install the appliance in a safe and
suitable place that meets installation
requirements.
• The appliance is equipped with an
electric cooling system. It must be
operated with the electric power supply.
Cabinet minimum
height (Cabinet un‐
der the worktop mini‐
mum height)
590 (600) mm
Cabinet width
560 mm
Cabinet depth
550 (550) mm
Height of the front of
the appliance
594 mm
Height of the back of
the appliance
576 mm
Width of the front of
the appliance
595 mm
Width of the back of
the appliance
559 mm
Depth of the appli‐
ance
569 mm
Built in depth of the
appliance
548 mm
Depth with open
door
1022 mm
Ventilation opening
minimum size. Open‐
ing placed on the
bottom rear side
560x20 mm
Mains supply cable
length. Cable is
placed in the right
corner of the back
side
1500 mm
Mounting screws
4x25 mm
Electrical connection
WARNING! Risk of fire and
electric shock.
• All electrical connections should be
made by a qualified electrician.
• The appliance must be earthed.
• Make sure that the parameters on the
rating plate are compatible with the
electrical ratings of the mains power
supply.
• Always use a correctly installed
shockproof socket.
• Do not use multi-plug adapters and
extension cables.
• Make sure not to cause damage to the
mains plug and to the mains cable.
Should the mains cable need to be
replaced, this must be carried out by
our Authorised Service Centre.
• Do not let mains cables touch or come
near the appliance door or the niche
below the appliance, especially when it
operates or the door is hot.
• The shock protection of live and
insulated parts must be fastened in
such a way that it cannot be removed
without tools.
• Connect the mains plug to the mains
socket only at the end of the
installation. Make sure that there is
access to the mains plug after the
installation.
• If the mains socket is loose, do not
connect the mains plug.
• Do not pull the mains cable to
disconnect the appliance. Always pull
the mains plug.
• Use only correct isolation devices: line
protecting cut-outs, fuses (screw type
fuses removed from the holder), earth
leakage trips and contactors.
• The electrical installation must have an
isolation device which lets you
disconnect the appliance from the
mains at all poles. The isolation device
must have a contact opening width of
minimum 3 mm.
• This appliance is supplied with a main
plug and a main cable.
4