background image

22

TOMTAR  /  Bedienungsanleitung Rollator FAKTO+ Arthritis  /  Version 1.0.0 DE

TOMTAR  /  User manual FAKTO+ Arthritis /  Version 1.0.0 DE / EN

DIMENSIONS AND TECHNICAL DATA

Description

Unit

FAKTO+ Arthritis

article number

   347NPU

material / color:  frame 

steel tube, powder coated, weldet / mangan grey

material / color / size: wheels

PU, non marking / dark grey /   200/50mm

material / color:  stacker, brake leaver

nylon glass fiber / black

material / color: grips // armrests

PVC / black // PU-foam / black

material / color: seat // tray

PP / black // acrylic / transparent

material / color: basket 

steel, powder coated / grey

 

size seat: width x hight x depth

mm

380 x 595 x 190

dimensions folded, lying (H / W / L)

mm

505 / 640 / 1120

dimensions folded, lying, w/o T-tubes

mm

250 / 640 / 685 

overall width

mm

580

overall hight min. / max.

mm

1155  / 1325

turning circle (diameter)

mm

1150

tilting stability forward

° 

10,0 (according to EN ISO 11199-3:2005)

tilting stability backwards

°

4,0 (according to EN ISO 11199-3:2005)

tilting stability sidewards 

°

3,5 (according to EN ISO 11199-3:2005)

adjustability height T-tubes with 
armrests

8

8 drillings (with stargrip screws) to ever 25 mm

hight armrests min. / max. 

mm

890 / 1145 

weight without / with accessories

kg

10 / 11

maximum user weight
incl. payload

kg

120

max. load accessories

kg

basket: 5 / tray: 5 / stacker: 7

recommended height

m

1,55 - 1,85

09 TECHNICAL DATA

Summary of Contents for Tomtar FAKTO+ Arthritis

Page 1: ...EN FR IT NL EN Arthritis rollator User manual Version 1 0 0 DE ...

Page 2: ...itis Rollator from DIETZ Please read this user manual carefully before first using the new FAKTO Arthritis It contains important safety instructions and valuable tips on correctly using and caring for the FAKTO Arthritis rollator If you have any questions or require additional information please contact the specialist retailer which supplied the wheelchair to you These operating instructions conta...

Page 3: ...10 05 Accessories Add ons Basket fitted as standard 10 Rack fitted as standard 10 Tray fitted as standard 11 Single hand brake optional 11 Add ons Accessories of Third partys 11 06 Safety instructions Safety instructions 12 07 Instructions for general use Servicing maintenance 14 Maintainance schedule 15 Fault finding and rectification 17 Cleaning 18 Desinfection 18 Forwarding and reusing 18 Stora...

Page 4: ...obility especially rheumatism and arthritis patients with a maximum body weight of 120 kg for use as a walking aid and to a limited extent as a seating device for tem porary rest It is used both domestically as well as in hospi tals and is designed exclusively for use on solid and level indoor surfaces The intended use may differ for products which were manufactured as custom made device and which...

Page 5: ...unc tions SCOPE OF DELIVERY The scope of delivery of FAKTO Arthritis consist of c c FAKTO Arthritis rollator c c Basket c c Tray c c User manual c c Rack Optional Accessories c c One handed brake Art 290107 left Art 290108 right On reception of your new rollator please check the delivery for completeness and damage If damage is evident please contact your seller immediately WARNING Keep foil away ...

Page 6: ... Brake pads Front wheel swivel wheel Basket Main frame Push handle T tube armrest Seat Adjusting screw brake Adjusting screw cable Brake cable Brake lever Rack plastic Basket hooks Type label Warning notice Star knob screw for hight adjustment 6 TOMTAR Bedienungsanleitung Rollator FAKTO Arthritis Version 1 0 0 DE TOMTAR User manual FAKTO Arthritis Version 1 0 0 DE EN SET UP ROLLATOR FAKTO ARTHRITI...

Page 7: ...sm fold down the lever until it engages firmly in the guide 1 pic 2 1 pic 2 NOTE To use FAKTO Arthritis correctly it must be ad justed to your individual size You should have an employee of your medical supply store or another trained person do this Fitting the armrests Loosen the star screws of the two T pipes The T pipes can now be inserted into the vertical tubes of the frame 1 pic 3 The clampi...

Page 8: ...ct your medi cal supply store or an authorised specialist re tailer 1 2 3 4 6 7 5 pic 3 Adjusting armrests handles Now adjust the correct height of the armrests and the position of the handles Insert the hexagonal screw 4 pic 3 from the inside of the main frame through the borehole Now guide the curved washer over the screw thread Ensure that the hexagonal head of the screw is seated in the hexago...

Page 9: ...rake and parking brake The brakes are operated using the brake han dles mounted on the handles To brake while moving pull the two brake han dles towards you evenly 1 pic 6 1 2 pic 6 To brake the rollator safely and indefinitely when stationary for example to sit push the brake handle firmly away from you 2 pic 6 The brake handle engages securely and audibly in this position Pull the brake handle t...

Page 10: ... storage and transportation of larger goods or items up to a maximum of 5 kg To remove the basket lift if off the hooks un derneath the seat The hook can now be folded upwards so that you can pick up the basket To attach the basket to the rollator simply fit it back onto the hooks Make sure that the basket is securely attached before placing items inside Rack fitted as standard The plastic rack un...

Page 11: ...The same usage and maintenance in structions apply as for the version with brakes on both handlebars ADD ONS ACCESSORIES OF THIRD PARTYS In general only original accessories from DIETZ GmbH may be used If third party products are installed on the rollator responsibility for the safety of the product passes to the person who installs the accessories or carries out the instal lation The conformity o...

Page 12: ...pping over when standing and moving with the rollator due to the high armrests There fore always ensure that the load on the rollator is even c c Pay attention to the neighbouring compo nents when operating the folding lock unlocking lever There is a risk of en trapment if handled improperly c c Never exceed the maximum combined load of 120 kg for user and load c c Avoid exposing the wheelchair to...

Page 13: ...bearings can be damaged by sand seawater and road salt Clean the rollator thoroughly if it has been exposed to conditions such as these c c If they cannot be bypassed ruts rails or similar obstacles must always be crossed at right angles 90 c c The rollator must not be used to transport heavy loads Items must only be transported using the rack basket or tray as described in the Accessories section...

Page 14: ...es stipulated in the maintenance schedule must be performed by the user or assistant if not otherwise stated WARNING Repairs on the rollator must only be performed by specialist shops using DIETZ original spare parts to maintain the operational safety of the rollator The relevant spare parts catalogue can be found on our website in the information of the product in question NOTE FOR SPECIALIST DEA...

Page 15: ...ut any issues 3 It must be possible to engage the lever right at the bottom in order to lock it x Screw connections Securely fastened All screw connections must be securely fastened Repeated loosening and re tightening causes self locking nuts and screws to lose their effectiveness These must therefore be replaced by a specialist retailer if they have become loose x Steering and running wheels Mob...

Page 16: ...lete Function damage 1 The two parts of the frame must not be damaged or cracked 2 Functional or surface damage must be rectified x Visual inspection Loose parts fractures corrosion or other damage If this type of damage is detected the rollator must no longer be used as safe operation is no longer guaranteed x Contamination Rollator complete The entire rollator must be cleaned in line with the le...

Page 17: ...tor is not fully unfolded Fully unfold the rollator and engage the folding lock The seat is defective or is incorrectly screwed onto the rollator Consult an authorised specialist retailer The hinges on the folding mechanism or the folding lock are defective The rollator does not provide secure support or does not stand reliably The armrests or push handles are not fixed in place properly or have b...

Page 18: ... listed in the maintenance schedule on the rollator CLEANING c c Regularly clean the rollator by wiping with a damp cloth c c In the event of heavier contamination use a mild cleaning agent and warm water c c The wheels can be cleaned using a damp brush with soft plastic bristles c c Remove dirt and fluff from the wheel hubs c c After cleaning ensure that all materials are completely dried in orde...

Page 19: ...ing facility PRODUCT LABELLING Type and warning signs must always be kept legible With the FAKTO Arthritis these are at tached to the horizontal connecting bar of the main frame Please have unreadable or missing signs stick ers replaced immediately by your specialist dealer This includes the reflector stickers This information warning sign is located next to the type plate Gehhilfe für Innenbereic...

Page 20: ... Unique Device Identifer 01 UDI DI 10 Order number 21 serial number manufacturer manufacturer sign contact adress maximum user weight incl load Manufacturing date Total width rollator Total hight rollator min max Rollator for indoor use Follow the user manual Attention Please note the safety instructions in the operating instructions Medical Device CE mark 20 TOMTAR Bedienungsanleitung Rollator FA...

Page 21: ...E The expected product service life is five years when used daily and if used as intended This assumes compliance with the maintenance and safety specifications stipulated in this manual LIABILITY Dietz GmbH only bears liability if the products are used under the specified conditions and for the specified purposes We recommend that the products be handled appropriately and cared for according to t...

Page 22: ...ated grey size seat width x hight x depth mm 380 x 595 x 190 dimensions folded lying H W L mm 505 640 1120 dimensions folded lying w o T tubes mm 250 640 685 overall width mm 580 overall hight min max mm 1155 1325 turning circle diameter mm 1150 tilting stability forward 10 0 according to EN ISO 11199 3 2005 tilting stability backwards 4 0 according to EN ISO 11199 3 2005 tilting stability sidewar...

Page 23: ...to 45 C 20 to 75 relative humidity CAPTURE IDENTIFICATION DATA We recommend to write down your product identification data below so that you have these on hand when you require any further information about your product You ll find these data on the label attached to your product see chapter product labeling Typ model Item nr REF Serial number 21 Date of manufacture Other information The identific...

Page 24: ...red trade mark of DIETZ GmbH DIETZ GmbH Reutäckerstraße 12 76307 Karlsbad Germany Tel 49 7248 9186 0 Fax 49 7248 9186 86 info dietz reha de www dietz rehab de Misprint falsities price and product changes reserved DIETZ GmbH Reha Produkte Karlsbad Reproduction also extracts by written permission from DIETZ GmbH Karlsbad only ...

Reviews: