controller to continue irrigation at any month of the year, simply add back the checkmark. Repeat the steps
to activate or deactivate any additional months. Press
or
again to underscore OK. Press
to
continue.
This screen tests the solenoids for shorts and/or open wires.
In this screen, the Short and Open valve test is deactivated by
default (not checked). To enable the controller to activate one
or both of the two Short or Open features, simply add a checkmark. Press
or
to underscore the
appropriate box and press
to activate (checked) and
to deactivate. Repeat the steps to activate or
deactivate the other option. Press
or
again to underscore OK. Press
to continue.
NOTE:
The valve testing takes place when the valve is operated. Fault status will appear in Check
Status menu or during a Manual Run.
In this screen there are two options available for each valve. By
default all valves in the budget are activated and MV/P is deactivated.
This screen allows the user to activate or deactivate each valve
independently.
Option One MV/P:
If checked, the valve number will operate with master valve or pump.
Option Two Budget:
Is checked by default, the valve number is affected by the monthly budget setting.
To enable the controller to use any or both of the two features, simply add or remove the checkmark from
each valve. Press
or
to underscore the appropriate box and press
or
to activate
(checkmark) or deactivate (remove the checkmark). Press
or
again to underscore OK. Press
to continue
The Sensor In Use feature indicates whether or not a sensor is
activated and in use. If a sensor is installed, select Yes.
To enable the controller to use a sensor, the first step is to
indicate that a sensor is being used. Press
or
and
underscore Yes or No, then press
to select. Press
or
again to underscore OK. Press
to continue.
This screen, Sensor Location, indicates the location of the sensor. If
MV/P or other is selected, this is the location in which the sensor is
connected via the SKIT 8821-4 adapter.
To select sensor location, press
or
and underscore MV/P or other, then press
to select.
Press
or
again to underscore OK. Press
to continue. If other was selected, in the next screen
specify which station number the sensor(s) is/are governed by.
NOTE:
If MV/P is selected on the screen, sensor must connect to the master valve wire or terminal. If
other is selected, the sensor must be connected to one of the station’s numbered terminals.
If Other is selected, in this screen the sensor location must
be specified (to which station number the sensor(s) is/are
connected). Press
or
to underscore the digit number,
22
Active CCT Test
Short Open
Valve #1 Options:
MV/P
4
Budget
Sensor in Use?
l
Yes No
Sensor Location:
MV/P
l
Other
Sensor 01
Location:
s
t
s
t