Display Layout

  1. SCAN measuring indicator
  2. Data HOLD icon
  3. Laser pointer indicator
  4. Trigger lock indicator
  5. High alarm indicator
  6. Low alarm indicator
  7. MAX, MIN, AVG, and DIF icons
  8. °C and °F temperature icons
  9. USB icon (transmit data to PC)
10. Low-battery indicator
11.  Emissivity or type K temperature readout
12. Type K thermocouple icon
13. Emissivity icon
14. Current temperature readout
15.  Max, Min, Avg, or Dif temperature readout

11

10

7

15

14

13

12

7

8

9

1

2

3

4 5

6

Summary of Contents for 20250-07

Page 1: ...N PRECISION MEASUREMENT Professional Dual Laser Infrared Thermometer with 30 1 Distance to Sight Ratio USB Output Single Type K Input and Temperature Alarm with NIST Traceable Calibration Model 20250...

Page 2: ...ble emissivity temperature differential data Hold Max Min Avg readings and auto power off The meter also supports contact measurement through a type K thermocouple input The instrument is fully tested...

Page 3: ...ouple input Precise noncontact IR measurements Rapid detection function Adjustable emissivity from 0 10 to 1 0 User selectable C or F units Automatic data Hold MAX MIN AVG temperature displays Tempera...

Page 4: ...beam 3 Type K thermocouple input 4 USB computer interface 5 LCD 6 Up button 7 Backlight Laser button 8 Down button 9 MODE button 10 Lens cover with magnetic lock 11 Measurement trigger 12 Battery cov...

Page 5: ...6 Low alarm indicator 7 MAX MIN AVG and DIF icons 8 C and F temperature icons 9 USB icon transmit data to PC 10 Low battery indicator 11 Emissivity or type K temperature readout 12 Type K thermocouple...

Page 6: ...applications organic materials and painted or oxidized surfaces have an emissivity of 0 95 preset in the unit Inaccurate readings will result from measuring shiny or polished metal surfaces To compens...

Page 7: ...Charcoal powder 0 96 Earth 0 92 to 0 96 Lacquer 0 80 to 0 95 Water 0 92 to 0 96 Lacquer matte 0 97 Ice 0 96 to 0 98 Rubber black 0 94 Snow 0 83 Plastic 0 85 to 0 95 Glass 0 90 to 0 95 Timber 0 90 Cer...

Page 8: ...e is connected you cannot adjust emissivity b Trigger Lock Use for continuous monitoring of temperatures When the Lock icon is flashing use the Up or Down button to turn on Then press the MODE button...

Page 9: ...t the meter to your PC via the supplied USB cable 3 Power the meter on 4 Open the installed Data Transmission Software by double clicking on the icon on your PC desktop 5 The software will automatical...

Page 10: ...CD will show Operating temperature 32 to 122 F 0 to 50 C Storage temperature 14 to 140 F 10 to 60 C Weight 17 4 oz 494 g Dimensions 71 2 x 6 x 21 4 18 9 x 15 2 x 5 7 cm Power One 9 V battery Specifica...

Page 11: ...enance Recalibration and Repair Cleaning and Storage The meter should be cleaned with a damp cloth and mild detergent when necessary Do not use solvents or abrasives Store the meter in an area with mo...

Page 12: ...aintenance Recalibration and Repair continued It is recommended that Digi Sense products are calibrated annually to ensure proper function and accurate measurements however your quality system or regu...

Reviews: