MAX/MIN Button (Model 20250-54 only)
The MAX/MIN function allows the meter to capture the
highest or lowest reading for later reference.
1. Press the MAX/MIN button to begin measurement. The
indicator “MAX” or “MIN” will appear in the display.
2. If the “MAX MIN” messages are flashing, the instrument
is in MAX/MIN mode but not recording, press the
MAX/MIN button to select a mode.
3. To resume operation, hold down the MAX/MIN button
for 2 seconds.
PEAK Hold Button (Model 20250-54 only)
The PEAK Hold function captures the peak AC voltage or
current. The meter can capture negative or positive peaks
as fast as 1 millisecond in duration.
1. Set the rotary function switch to the A or V position.
2. Press the MODE button to select “AC”.
3. Allow time for the display to stabilize.
4. Press and hold the PEAK button until “CAL” appears in
the display.
5. This procedure will zero the range selected.
6. Press the PEAK button; the indicator “Pmax” will be
displayed.
7. The display will update each time a higher positive peak
occurs.
8. Press the PEAK button again; the indicator “Pmin” will
be displayed. The display will now update and indicate
the lowest negative peak.