1. INTRODUCTION 

 

This versatile handheld 
instrument provides highly 
accurate temperature 
measurements. The 
instrument is designed    
for easy operation and 
includes

 

the following 

features:

 

 

 

•  Menu driven setup and operation 

•  Data logging for up to 2000 points  

• USB output  

•  Operator selection of Celsius or 

Fahrenheit scale 

•  Resolution of up to 0.01°C/°F 

•  Large backlit LED and dot-matrix 

graphic LCD display 

•  Hold feature for temporarily retain  

a reading 

•  Displays minimum and maximum  

and average readings 

•  Field calibration capability 

•  Disabling of auto-off function  

• Low-battery warning 

• Bayonet connector input

www.

GlobalTestSupply

.com

Find Quality Products Online at:

sales@GlobalTestSupply.com

Summary of Contents for 91428-06

Page 1: ...rmistor Datalogging Thermometer Instruction Manual Single Input Data Logging Thermistor Thermometer Model 91428 06 68X001353 Rev0 0717 1065DGMAN_91428 06 www GlobalTestSupply com Find Quality Products...

Page 2: ...E 14 11 HOLD FUNCTON 15 12 MIN MAX and AVG FUNCTION 15 13 DATA LOGGING 15 14 SETUP MODE 16 15 GENERAL SETUP SCREEN 17 16 CALIBRATION SCREEN 19 17 ALARMS SCREEN 21 18 DATA LOGGING SCREEN 24 19 CALIBRAT...

Page 3: ...2000 points USB output Operator selection of Celsius or Fahrenheit scale Resolution of up to 0 01 C F Large backlit LED and dot matrix graphic LCD display Hold feature for temporarily retain a readin...

Page 4: ...nged in an area known to be nonhazardous CAUTION 1 Do not use or store this instrument in microwave ovens or any abnormally hot or cold areas 2 Weak batteries should not be left in the instrument Dead...

Page 5: ...e 99 99 Accuracy From 40 00 to 99 99 F 40 00 to 99 99 C 0 06 F 0 03 C From 100 0 to 257 0 F 100 0 to 125 0 C 0 1 F 0 1 C From 257 0 to 302 0 F 125 0 to 150 0 C 0 9 F 0 5 C Display Backlit dot matrix 5...

Page 6: ...torage temperature 40 C to 65 C 40 F to 149 F Humidity 10 to 90 RH noncondensing Battery life Size Three AA 1 5V alkaline Life 400 hours continuous typical without backlighting Dimensions Without armo...

Page 7: ...ection Meets IEC 529 IP 54 for dust and water resistant enclosures probe attached CE Compliance EN61326 1 A1 1998 EU EMC Directive www GlobalTestSupply com Find Quality Products Online at sales Global...

Page 8: ...ut the battery life indicator Indicator Voltage Cell 3 bars More than 4 1 V Cell 2 bars More than 3 6 V Cell 1 bars More than 3 0 V Cell empty bars flashing More than 2 85 V Adaptor power supply Main...

Page 9: ...laced 1 Before changing battery turn instrument off and disconnect thermistor 2 Loosen screw and lift battery cover off back of case 3 Remove the three AA batteries 4 Insert three new batteries observ...

Page 10: ...ushing the bottom edges of meter down to set it into position Lift up the stand at the back of meter for bench top applications if necessary 2 To remove thermometer from armor push out from the bottom...

Page 11: ...PTIONAL HANDS FREE ACCESORIES You can use the optional magnets and strap in the Hands Free Kit accessories for hands free operations www GlobalTestSupply com Find Quality Products Online at sales Glob...

Page 12: ...g connector on the top of the instrument If no probe is connected the display will read open Thermistors are sensitive at the tip or sensing element When taking measurements allow time for the reading...

Page 13: ...Toggle between F and C display F3 Toggle between menu and measure mode hold Freeze display on off light Turns meter on and off press and hold for 3 seconds to turn off Press momentarily to turn on bac...

Page 14: ...display features a large primary display smaller secondary displays for channel info or min max avg and helpful annunciators for added measurement data www GlobalTestSupply com Find Quality Products...

Page 15: ...logging indicator 10 Main reading display 11 Current reading unit indicator 12 Min Max Avg elapsed time 13 Current Min Max Avg reading indicator 14 Meter logging memory location 15 Measurement alarm a...

Page 16: ...e primary display Pressing the F2 key will toggle reading between F and C display Pressing the F1 key initiates and toggles through Minimum Maximum and Average reading modes Pressing F3 enter accesses...

Page 17: ...mum values are sensed and automatically stored To exit and clear this function press the F3 to access the Menu functions See the Clear Reset menu section for more details 13 DATA LOGGING Press the log...

Page 18: ...To enter a setup screen press Select F1 key To return to measurement mode press Meas F3 key Following menu options are listed 1 General Setup 2 User field calibration 3 Alarm settings 4 Data logging s...

Page 19: ...indicate you want to change the setting of the current parameter or recall or log to move to the next parameter Press recall or log to change the options Press F2 to choose the next setting Whenever...

Page 20: ...set change password In the event if uses forget his her password 5586 can be used to reset to a new value On the second page you can set time and date www GlobalTestSupply com Find Quality Products On...

Page 21: ...thermistor off set error It is NOT necessary to perform a field calibration to obtain specified meter accuracy Use the field calibration feature to improve thermometer probe accuracy or to compensate...

Page 22: ...00 F Slope adjusts at two points The two calibration points must be at least 20 00 C 36 00 F apart The 2nd calibration point should be at a higher value than the 1st calibration point Use the or keys...

Page 23: ...alarm setting options Measurement alarm Disable or enable the alarm by pressing recall or log and F1 to accept Increase or decrease individual limit by pressing recall or log Meter in alarm mode www...

Page 24: ...e the countdown alarm and set the countdown time from 5 sec to 1 hour After setting enabling the countdown alarm the measurement screen should look like this www GlobalTestSupply com Find Quality Prod...

Page 25: ...ountdown will stop the process You will need to restart the countdown by selecting the start key F2 Alternatively you can also choose Menu to go into the timer menu and disabling the alarm www GlobalT...

Page 26: ...lay should look like this To repeat the functions select F2 Note The C F function is disabled when the count down function is enabled To activate the C F function on measurement screen please go into...

Page 27: ...he Auto shutoff until the countdown is completed or manually stopped If the meter is manually or auto shutoff The Countdown Alarm is automatically reset to Disable each time the meter is shut off The...

Page 28: ...the logging methods as auto or manual If it is auto logging using recall or log to set time interval Its range is from 0 min to 60 min Data Transfer from Meter to Computer www GlobalTestSupply com Fi...

Page 29: ...minal NOTE METER MUST BE TURNED ON PRIOR TO CONNECTING USB CABLE OR COMPUTER MAY NOT RECOGNIZE THE INSTRUMENT 19 CALIBRATION REPORT SCREEN The Calibration report will show the time and date along with...

Page 30: ...oose which data you want to clear or reset For calibration logged data and reset all you will have to enter the password to proceed Default Password is 9900 www GlobalTestSupply com Find Quality Produ...

Page 31: ...AMP CLOTH Do not clean with abrasives or solvents Use mild detergents never immerse nor use excessive fluid 23 BATTERIES If there is no display when the meter is turned on check condition of the three...

Page 32: ...e connector Display shows Err If display shows this message other than during the field calibration mode please return the instrument for servicing Cannot connect to PC Ensure that the meter is powere...

Page 33: ...28 06 Rubber armor with stand 35427 80 Hands free kit two magnets and a strap 35427 85 General purpose probe Immersion into liquids 08491 06 Flexible general purpose probe vinyl sheath 08491 02 USB ca...

Page 34: ...ulting from product misuse or abuse may be invoiced to you 27 PRODUCT RETURN To limit charges and delays contact the seller or Manufacturer for authorization and shipping instructions before returning...

Page 35: ...er quality standards Conformity ISO IEC 17025 2005 accredited NIST Handbook 150 2000 Edition ANSI NCSL Z540 2 1997 NIST Technical Note 1297 ISO 9000 2000 Fast Service Our substantial inventory of repl...

Page 36: ...documentation you need to meet your most stringent quality requirements for the control of inspection measuring and test equipment Certification includes certificate of calibration with test data inc...

Page 37: ...time to recalibrate your instrument Are your calibration certificates good enough InnoCal surpasses the competition by providing the most complete certificates as required by NIST All of our certific...

Page 38: ...ds Meter only Probe only System meter probe Four test points across range of instrument 0 100 165 230 C 4 32 446 770F 17000 06 17001 06 17002 06 InnoCal The Choice of Quality www GlobalTestSupply com...

Page 39: ...his product please contact the Manufacturer or authorized seller 1065DGMAN_91428 06 Formatted Font 9 pt Bold Formatted Left Indent Left 0 08 12 pt Formatted Left Indent Left 0 08 12 pt www GlobalTestS...

Reviews: