Configure the AnywhereUSB Plus Hub from the CLI
set ethernet
AnywhereUSB® Plus User Guide
140
set ethernet
Note
This command applies to the AnywhereUSB 24 Plus only.
Purpose
Configures the bonding mode for the Ethernet network. The Hub has two physical Ethernet network
ports that use the same MAC address and share one IP address. When both ports are being used, they
act as one Ethernet network port.
You can also configure bonding in the web UI. See
Syntax
set ethernet [
option]
Option
bonding=[active-backup|balance-rr]
active-backup
The Hub uses only one of the Ethernet network connections at a time. If one Ethernet
network connection fails, all data is sent from the second Ethernet network connection.
balance-rr
The Ethernet network connection alternates between the two ports as the Hub sends
data. If one Ethernet network connection fails, all data is sent from the second Ethernet
network connection.
Examples
Configure fault tolerance (active backup)
#> set ethernet bonding=active-backup
Configure load balancing (round robin)
#> set ethernet bonding=balance-rr