Digi ConnectTank Getting Started Guide
Page 16
Configurable Parameters Related to the Device Settings Group
The following table describes the configurable parameters of the Device Settings group.
Name
Description
Range
Default
Read sensor every
Based on this parameter
value, sensor reads liquid
level every x minutes.
15 minutes to 1440
minutes (24 hours)
720 minutes (12 hours)
Report sensor data
every
Based on this parameter
value and the
Read
sensor every
parameter
value, device publishes
data to Device Cloud.
Example: Read sensor
= 15 Report sensor =4
Sensor reading will be
published to Device Cloud
every 1 hour (15 minutes
x 4 times).
1 to 672 readings
Note: The sensor can
only store 96 readings.
Setting this value above
96 will lead to lost data.
1
First daily report at
HHMM
A value of 60 would be 1
hour after midnight GMT
(minutes from midnight
GMT).
0 to 1439 (minutes)
0
Send last
Sends number of latest
readings. A value of 1
means only send the last
reading. This parameter
value must be less than
the
Report sensor data
every
value.
1 to 96 readings
1