COMPASS MODE:
- Direction showing in the current location
Path
Press
3 until the
mode indicator is below
“COMP”
Field 1
Cardinal point abbreviation
Field 2
Bearing in degree
Field 3
Current time
Outer
Circumference
Graphically displays the North
and South arrows when 1
–
segment lit is the North
Use of Compass
-
Compass displays actively for 30 second → goes into sleep
mode and “- --o” will show on field 2 → press either (S3) or (S4) to
reactive the compass
Note
- Calibration of compass is required for the first time or after battery
replacement.
Calibration of Compass
- Compass should be calibrated when it is subjected to close
proximity of magnetic sources, extreme cold weather, every time
the battery is replaced or suspected that any environmental
conditions have affected the compass reading.
Adjust
-
Hold (S2) for 1 second, → “
CMP
” will be displayed on field 1,
“
PUSH-
” will begin to flash on field 2 and “
CAL
” will display on field
3.
-
Press (S3) to start the calibration → “360° ” will be displayed on
field 2 and the outer circumference displays all segment lit
- Hold the watch on observer level and slowly rotate it in either
clockwise or anti
– clockwise direction, for 1 complete turn. →
“
DONE
” will be displayed on field 2 when all segments disappear
→ Press (S1) to accept the setting
Note
- The watch will return to Time Main Mode after 30 minutes.
OTHER FUNCTIONS:
Measurement Units:
There are two unit groups of measurement, They are metric such
as (M, mbar,
C
, M/Min) and imperial such as (Ft, inHg,
F
,Ft/Min)
Setup
-
Press (S1) until the mode indicator is directly below “
TIME
”
→ Hold (S1) and (S2) for 1 second→ Field 1 will firstly display
“
SET
” for 2 second, and then display “
UNI
” and the preset units
→ Hold (S2) for 1 second, “
M
” or “
Ft
” located on field 2 will
begin to flash
-
Press (S2) to select “
M
” or “
Ft
” → “
mbar
” or “
inHg
” → “
C
” or “
F
” → “
M/Min
” or “
Ft/Min
”
- Press (S3) or (S4) to set the function
- Press (S1) to accept the setting
Backlight:
-
Hold (S1) for 1 second, → backlight will turn on for 5 seconds
→ Press any key when the backlight is on will keep the light for
another 5 seconds
Note
- To ensure sufficient electric current for pressure sensor, the EL
backlight is disabled automatically during sensing and it will turn
on for 5 seconds after finishing the sensing.
Low Battery Indicator :
The low battery indicator will be turned on when the battery
voltage level drops below 2.5V in eight out of ten times.
Fast Button Features:
In any mode, press (S3) will go to the fast button feature
immediately. After 12 seconds, it will return to the original mode
that you were viewing before.
The Fast button feature allows the user to check the cumulative
vertical ascent or descent, the number of laps of current logbook
or the last logbook. These three displays will show sequentially
with a 4 second interval.
Key tone:
Press any button will have a “beep” sound.
System Reset and diagnostics:
After resetting the watch, the system will be reinstalled. All
memories such as logbook, logbook history, difference
measurements in altimeter and barometer, 24-hour memory and
4-day memory, will be cleared.
The date and time format will be at 12:00am, 1 Jan 2002, 12
hour format and unit is metric.
The diagnostic mode is entered upon system reset; all the LCD
segments will be lit and the buzzer will be turned on for 3 seconds.
MEASUREMENT SPECIFICATIONS:
Sensor Measurement:
Mode
Frequency of measurement
4 day memory mode
1 per hour
24 hour memory mode
1 per hour
Altimeter main mode
1 per sec for the first 2 secs, thereafter is
depended on the Weighted Current
Rate.
Barometer main mode
1 per 10 secs
Compass main mode
Deactivate after 30 secs
Difference
measurement in
Altimeter mode
1 per 10 secs
Note
- Please refer to the remark of Altimeter for the details of Weighted
Current Rat
Ranges and Resolution:
Altimeter
-499m to 9001m or
–1600ft to 29500ft
Barometer
299mbar to 1101mbar or 8.9inHg to
32.40inHg
Calendar
1 Jan, 2002 to 31 Dec, 2099
Sea Level Pressure
299mbar to 1101mbar or 8.9inHg to
32.40inHg
Temperature
-10 °
C
to 60 °
C
or 14 °
F
to 140 °
F
.
Resolution
Altimeter
1m or 3 ft
Barometer
1mbar or 0.05inHg
Compass
1° for bearing and ± 3° for North
– South
Direction
Temperature
0.1 °
C
or 0.1 °
F