MIL-3000FTX Series of FastPort Print Servers
A-3
A.5 Connectors
A.5.1 Serial Port Connector
A.5.2 RJ-45 Connector
• Pin 1: Transmit data +
Pin 3: Receive data +
• Pin 2: Transmit data -
Pin 6: Receive data -
A.5.3 Parallel Port Connector
A.6 Environmental Operating Conditions
A.7 System LEDs
PIN Number
Signal
PIN Number
Signal
1
NC
6
NC
2
RXD
7
RTS/DTR
3
TXD
8
CTS
4
DTR/RTS
9
NC
5
GND
PIN Number
Signal
PIN Number
Signal
PIN Number
Signal
1
PASTB
10
ACK
19
GND
2
PAD0
11
BUSY
20
GND
3
PAD1
12
PE
21
GND
4
PAD2
13
ONLINE
22
GND
5
PAD3
14
AUTO FEED
23
GND
6
PAD4
15
FAULT
24
GND
7
PAD5
16
INIT
25
GND
8
PAD6
17
SLCTIN
9
PAD7
18
GND
Parameters
Minimum
Maximum
Operating Temperature
+5° C
40° C
Humidity: Non-condensing
10% 95%
Altitude test
NA
40,000 ft. (at 40° C)
Temperature test (Operating)
5° C
50° C
Temperature test (Packaged)
-25° C
70° C
LED
Functioned
Color
RX
Transmitting on the network
Green
TX
Receiving from the network
Green
SYS
System is active
Green
SER
Serial port activity
Green
PWR
System power is On
Green
LNK
Link is active
Yellow
NET
Network activity
Yellow
P1
Parallel data activity on parallel port 1
Yellow
P2 (MIL-3200FTX & MIL-3310FTX only)
Parallel data activity on parallel port 2
Yellow
P3 (MIL-3310FTX only)
Parallel data activity on parallel port 3
Yellow