Frame descriptions
Secure Session Control frame - 0x2E
Digi XBee® 3 802.15.4 RF Module User Guide
206
Secure Session Control frame - 0x2E
Description
Use this frame to control a secure session between a client and a server. If the remote node has a
password set and you set the frame to login, this will establish a secure session that will allow
secured messages to be passed between the server and client.
This frame is also used for clients to log out of an existing secure session.
If the frame is addressed to a broadcast address, the login attempt will fail with an invalid value
(status
0xA
) error.
Format
The following table provides the contents of the frame. For details on frame structure, see
Frame
data
fields
Offset Description
Frame
type
3
0x2E - Control Frame
64-bit
source
address
4-11
The 64-bit address of the destination device.
Broadcast transmissions are not allowed.