Modes
Idle mode
Digi XBee® 3 802.15.4 RF Module User Guide
78
2. If the device does not receive any valid AT commands within the time specified by
, it returns to Transparent or API mode. The default Command mode
timeout is 10 seconds.
For an example of programming the device using AT Commands and descriptions of each configurable
parameter, see
.
Idle mode
When not receiving or transmitting data, the XBee 3 802.15.4 RF Module is in Idle mode. During Idle
mode, the device listens for valid data on both the RF and serial ports.
If configured for
, the XBee 3 802.15.4 RF Module only transitions to a low power state
when in Idle mode.
Transmit mode
Transmit mode is the mode in which the device is transmitting data. This typically happens after data
is received from the serial port.
Receive mode
This is the default mode for the XBee 3 802.15.4 RF Module. The device is in Receive mode when it is
not transmitting data. If a destination node receives a valid RF packet, the destination node transfers
the data to its serial transmit buffer.