AT commands
Special commands
XBee 868LP RF Modules User Guide
128
Special commands
The following commands are special commands.
AC (Apply Changes)
Immediately applies new settings without exiting Command mode.
Parameter range
N/A
Default
N/A
FR (Software Reset)
Resets the device. The device responds immediately with an
OK
and performs a reset 100 ms later.
If you issue
FR
while the device is in Command Mode, the reset effectively exits Command mode.
Parameter range
N/A
Default
N/A
RE (Restore Defaults)
Restore device parameters to factory defaults.
Parameter range
N/A
Default
N/A
WR (Write
Writes parameter values to non-volatile memory so that parameter modifications persist through
subsequent resets.
Note
Once you issue a
WR
command, do not send any additional characters to the device until after
you receive the
OK
response.
Parameter range
N/A
Default
N/A