AT commands
Addressing commands
XBee 868LP RF Modules User Guide
135
Parameter range
1 - 5
Default
3
MR (Mesh Unicast Retries)
Set or read the maximum number of network packet delivery attempts. If
MR
is non-zero, the packets
a device sends request a network acknowledgment, and can be resent up to
MR
+1 times if the device
does not receive an acknowledgment.
We recommend that you set this value to
1
.
If you set this parameter to
0
, it disables network ACKs. Initially, the device can find routes, but a
route will never be repaired if it fails.
Parameter range
0 - 7
Default
1
Addressing commands
The following AT commands are addressing commands.
SH (Serial Number High)
Displays the upper 32 bits of the unique IEEE 64-bit extended address assigned to the XBee in the
factory.
Parameter range
0 - 0xFFFFFFFF [read-only]
Default
Set in the factory
SL (Serial Number Low)
Displays the lower 32 bits of the unique IEEE 64-bit RF extended address assigned to the XBee in the
factory.
Parameter range
0 - 0xFFFFFFFF [read-only]
Default
Set in the factory