AT commands
Diagnostic commands
XBee/XBee-PRO S2C 802.15.4 RF Module User Guide
103
For example, if
DB
returns 0x60, then the RSSI of the last packet received was -96 dBm.
If the XBee/XBee-PRO S2C 802.15.4 RF Module has been reset and has not yet received a packet,
DB
reports
0
.
This value is volatile (the value does not persist in the device's memory after a power-up sequence).
Parameter range
0 - 0xFF [read-only]
Default
N/A
EC (CCA Failures)
ReSets or displays the count of Clear Channel Assessment (CCA) failures. This register increments
when the device does not transmit a packet because it detected energy above the CCA threshold level
set with
CA
command. This count saturates at its maximum value. Set the count to zero to reset the
count.
Parameter range
0 - 0xFFFF
Default
N/A
EA (ACK Failures)
Resets or displays the count of acknowledgment failures. This register increments when the device
expires the retries without receiving an ACK on a packet transmission. This count saturates at its
maximum value. Set the count to zero to reset the count.
Parameter range
0 - 0xFFFF
Default
N/A
DD (Device Type Identifier)
Stores the Digi device type identifier value. Use this value to differentiate between multiple XBee
devices.
If you change
DD
,
will not restore defaults. The only way to get
DD
back to
default values is to explicitly set it to defaults.
Parameter range
0 - 0xFFFFFFFF
Default
0x10000