Operate in API mode
Frame descriptions
XBee/XBee-PRO S2C 802.15.4 RF Module User Guide
118
The device will continue to operate at the current baud rate until the change is applied with a
subsequent
AC
command.
The corresponding
with a matching Frame ID will indicate whether the parameter change
succeeded.
7E 00 05
09 53 42 44 07
16
Frame type
Frame ID
AT command
Parameter value
0x09
0x53
0x4244
0x07
Request
Matches response
"BD"
7 = 115200 baud
Query local command parameter
Query the temperature of the module (
TP
command).
The corresponding
frame with a matching Frame ID will return the temperature value.
7E 00 04
09 17 54 50
3B
Frame type
Frame ID
AT command
Parameter value
0x09
0x17
0x5450
(omitted)
Request
Matches response
"TP"
Query the parameter