Operate in API mode
Frame descriptions
XBee/XBee-PRO S2C 802.15.4 RF Module User Guide
138
Remote AT Command Response- 0x97
Request frame:
Remote AT Command Request - 0x17
Description
This frame type is emitted in response to a
Remote AT Command Request - 0x17
. Some commands
send back multiple response frames; for example, the
ND
command. Refer to individual AT command
descriptions for details on API response behavior.
This frame is only emitted if the Frame ID in the request is non-zero.
Format
The following table provides the contents of the frame. For details on frame structure, see
Offset Size
Frame Field
Description
0
8-bit
Start
Delimiter
Indicates the start of an API frame.
1
16-bit
Length
Number of bytes between the length and checksum.
3
8-bit
Frame type
Remote AT Command Response -
0x97
4
8-bit
Frame ID
Identifies the data frame for the host to correlate with a prior
request.
5
64-bit
64-bit
source
address
The sender's 64-bit address.
13
16-bit
16-bit
source
address
The sender's 16-bit network address.
15
16-bit
AT
command
The two ASCII characters that identify the AT Command.
17
8-bit
Command
status
Status code for the host's request:
0x00
= OK
0x01
= ERROR
0x02
= Invalid command
0x03
= Invalid parameter
0x04
= Transmission failure
Statuses for Secured remote AT commands:
0x0B
= No Secure Session - Remote command access
requires a secure session be established first
0x0C
= Encryption error
0x0D
= Command was sent insecurely - A Secure Session
exists, but the request needs to have the appropriate
command option set (bit 4).