AT commands
Networking and security commands
XBee/XBee-PRO S2C 802.15.4 RF Module User Guide
78
The binary equivalent of the default value (0x06) is 00000110. ‘Bit 0’ is the last digit of the sequence.
Default
0
AI (Association Indication)
Reads the Association status code to monitor association progress. The following table provides the
status codes and their meanings.
Status
code
Meaning
0x00
Coordinator successfully started, End device successfully associated, or operating in peer
to peer mode where no association is needed.
0x03
Active Scan found a PAN coordinator, but it isn't currently accepting associations.
0x04
Active Scan found a PAN coordinator in a beacon-enabled network, which is not a
supported feature.
0x05
Active Scan found a PAN, but the PAN ID doesn't match the configured PAN ID on the
requesting end device and bit 0 of
A1
is not set to allow reassignment of PAN ID.
0x06
Active Scan found a PAN on a channel that does not match the configured channel on the
requesting end device and bit 1 of
A1
is not set to allow reassignment of the channel.
0x0C
Association request failed to get a response.
0x13
End device is disassociated or is in the process of disassociating.
0xFF
Initialization time; no association status has been determined yet.
Parameter range
0 - 0x13 [read-only]
Default
N/A
DA (Force Disassociation)
Causes the End Device to immediately disassociate from a Coordinator (if associated) and re-attempt
to associate.
Parameter range
-
Default
-
FP (Force Poll)
The
FP
command is deferred until changes are applied. This prevents indirect messages from arriving
at the end device while it is operating in Command mode.