20
2.4.2 POWER SUPPLY OUTPUTS
The Vega Video’s clamp strip is provided with 2 power supply outputs to power any possible presence
detection sensor.
To power the sensor you only need to connect the Vega Video’s pin 1 to the positive contact (+) of the
presence detector and the Vega Video’s pin 2 to the negative contact (–) of the presence detector. To
connect and power a second presence detector you must connect the Vega Video’s pin 3 to the positive
contact (+) of the presence detector and the Vega Video’s pin 4 to the negative contact (–) of the presence
detector.
When using the backup battery, the power supply outputs are subject to a deterioration of around 3
Volts.
2.4.3 CONNECTION OF A PRESENCE DETECTOR TO THE VEGA VIDEO
Together with the above-mentioned information, herewith you will find a diagram and a table with the
description of the pins to use for a direct connection of a presence detector to the Vega Video.
PRESENCE DETECTOR
VEGA VIDEO
PIN +
PIN 1
PIN –
PIN 2
PIN N
PIN 5
PIN C
PIN 6
PRESENCE DETECTOR
VEGA VIDEO