10
ATTENTION
:
Since the
installation requires floor
CATRAX Master’s
drilling, it is important that the location be chosen carefully.
5.2 Floor drilling
and column fixation
Before installing
, check:
CATRAX Master
1. The place chosen for the installation.
2. If there is a power source or electric socket nearby (ducts for connection).
3. If the place chosen is adequate for the installation of the access controller
(indoors).
4. If access to the the
locks is clear.
CATRAX Master's
5. If there will be enough space for the arms after
is assembled. For
CATRAX Master
more details on the equipment's dimensions, see item 8. Technical characteristics.
6. If the floor is in conditions to receive anchor bolts (minimum of 4 cm of FCK15
M.P.A. concrete or equivalent).
Once you observe these recommendations, proceed to the installation:
1.
rill the floor with 3/8” drills (then use a 12mm or the ½” drill). Make two holes in
D
each column of
, according to the measures indicated in the image
CATRAX Master
below:
2. Clean the holes, removing any debris from drilling.
3. Place the external part of the bolts in the holes. Leave about 25mm of the bolt out of
the hole.
4. Position the column and fasten it to the floor with the four screws that accompany
the bolts. Use a flex-head socket wrench with ¾'' or an articulated socket wrench.
master
5
(0,196")
209
(8,228")
30
(1,181")
80
(3,149")
941
(37,047")
1001
(39,409")
12,5 (4X)
35
(1,377")