23
6.7.3 Configuration of control board – Switch Ds1
The switch (or dipswitch) DS1 allows programming the following actions:
-passage direction
-Maximum time for turns
-NO inputs (relay or pushbutton contact normally open and without input voltage),
enabling passage in face of these signals; or NC inputs (relay or pushbutton contact
usually closed and with input voltage), enabling passage in the absence of these
signals.
-enabling of a signal for a sound alarm if the access control remains at mid turn for
more than 5 seconds.
To program DS1, put each pin in the desired position, according to the table below:
01
02
03
04
05
06
07
08
Cleared in both directions
-
-
-
OFF
OFF
-
-
-
Blocked from left to right
-
-
-
ON
OFF
-
-
-
Blocked form right to left
-
-
-
OFF
ON
-
-
-
Blocked in both directions
-
-
-
ON
ON
-
-
-
NO inputs
-
ON
-
-
-
-
-
-
NC inputs
-
OFF
-
-
-
-
-
-
Enables sound signal
ON
-
-
-
-
-
-
-
Disables sound signal
OFF
-
-
-
-
-
-
-
Enables sound signal in mid-turn -
-
-
-
-
ON
-
-
Disables sound signal in mid-turn
-
-
-
-
-
OFF
-
-
Wait until first turn
-
-
-
-
-
-
ON
ON
Wait for 5 seconds
-
-
-
-
-
-
OFF
ON
Wait for 10 seconds
-
-
-
-
-
-
ON
OFF
Wait for 15 seconds
-
-
-
-
-
-
OFF
OFF
Habilitation per border*
-
-
OFF
-
-
-
-
-
Habilitation per level**
-
-
ON
-
-
-
-
-
6.7.4 Examples of some configurations
1
–
To receive a relay pulse (NO contact), clear the turning and wait to turn for 10 seconds:
1
2
3
4
5
6
7
8
Configuration
-
ON
OFF
ON
ON
-
ON
OFF
2
–
To leave the clockwise direction Always cleared and, when the HAB2 (anti-clockwise)
clearance signal is received, clear passage for undetermined period:
1
2
3
4
5
6
7
8
Configuration
-
ON
OFF
OFF
ON
-
ON
ON
3
–
To clear the turning while the relay has the contact closed and, as soon as the relay
contact is open, remove clearance:
1
2
3
4
5
6
7
8
Configuration
-
ON
ON
ON
ON
-
ON
ON
master
*
“
Habilitation per border
”
means that
will be enabled by a pulse at
CATRAX Master
the entry border (NC inputs) or exit border (NO inputs).
**
“
Habilitation per level
”
means that
will remain free as long as
CATRAX Master
there is an input signal.