Page 9
Below the altimeter A1 is there the A2-A3 altimeter display . To switch between A2 or A3
press the
key.
To zero the A2, A3 altimeter press the
key (long press).
4.2.1
ADJUSTING ALTIMETERS A1, A2, A3
Go to the altimeter menu “ALTIMETER” and select which altimeter
(A1 or A2 and A3) you want to adjust. Move up and down using
the arrow keys
,
and press the
key (function “EDIT”). To
adjust the altimeter value use the arrow keys
,
and confirm
with the
key (function “SAV”) or leave without saving with the
key (function “ESC”).
To reset the A1, A2, A3 altimeters to standard QNH (1013 mb), go
to the altimeter menu “ALTIMETER”. Press the
central key
(long press). A confirmation of “YES” or “NO” is required.
If the altimeters have been set in feet and the “ft” icon is blinking,
the altitude indication is in tens of feet.
4.3
VARIOMETER DISPLAY
4.3.1
SUPERFAST INTELLIVARIO
The Intellivario is a revolutionary system designed by Digifly which is based on the use of
sophisticated digital filters. This results in a very sensitive vario and is immune to radio
interference. All the variometric functions are subject to these filters.
The Digifly Archimede has a very fast pressure sensor and an excellent data acquisition
system that allows the instrument to perform as a very fast and accurate vario (updated
20 times a second).
4.3.2
VARIO REACTIVITY
To adjust the reactivity of the vario, go to (M-SET \ n. 5 RVAR).
4.3.3
ANALOGUE VARIO
The long data field on the left of the display shows the analogue vario value.
The analogue vario is an instantaneous vario reading. This information is shown on the
analogue display on the left of the screen by a bar graph, indicating lift or sink.
The scale of the analogue vario can be adjusted by setting parameter (M-SET \ n. 7
FS_V) to 1, 6, 12 m/s.
Summary of Contents for Archimede
Page 1: ...Software Version 61 2 ...