background image

 RFID Interface

Bolt Mechanism

Shared Use Functionality

Product Guide

R F ID

CARD

Manager

Setup

Programming Instructions

2

Locks are shipped with factory default settings (only operates by pressing

 `

). Setup must be completed to program the Programming Key 

and Manager Keys or Manager RFID Credentials to all the locks. 

Insert the Programming Key.
A two-tone beep will be heard 
and the LED will turn on. 

While the LED is on, insert one 
Manager Key or present one 
Manager RFID Credential at a time.
A two-tone beep will be heard for 
each Manager Key or Manager 
RFID Credential programmed.

Insert the Programming Key.
A two-tone beep will be heard 
and the LED will turn off. 

Repeat above steps for each lock 
or follow instructions to Express 
Register Manager Credentials to 
set up all locks.

Express Register Manager Credentials

The Programming Key can quickly program the same Manager Keys and Manager RFID Credentials to operate multiple locks. 

Go to the lock already programmed to operate with the Manager Keys and 
Manager RFID Credentials. 
Press and hold

 `

 for 10 seconds (a two-tone beep will be heard after 5 

seconds followed by 2 sets of two-tone beeps after 10 seconds) then release. 
The LED will turn on. 

While the LED is on, insert the Programming Key Insert the Programming Key. 
A two-tone beep will be heard and the LED will turn off. 

At each lock to be programmed, insert the Programming Key. 
A two-tone beep will be heard and the LED will fl ash once to indicate 
successful programming. 

To end Express Registration mode: 
Go to any programmed lock.
Press 

`

 then insert the Programming Key. 

Press 

`

 then insert the Programming Key again to return the bolt to the 

original position.* 

1

3

2

4

1

3

2

4a

4b

* The Programming Key will continue to function in Express Registration mode until it is used to operate a lock.

Summary of Contents for Next Cue

Page 1: ... unique to the lock system Keys User Key Manager Key Programming Key Operates the lock Overrides user access Allows management inspection Provides external power Programs Manager Keys Sets lock functionality Up to 25 Manager Keys may be programed to each lock 1 Programming Key allowed per lock group NextLock logo must face up Front Unit Key Button Key Slot Reader Rear Unit Key Insertion Cover Plat...

Page 2: ... Manager Credentials The Programming Key can quickly program the same Manager Keys and Manager RFID Credentials to operate multiple locks Go to the lock already programmed to operate with the Manager Keys and Manager RFID Credentials Press and hold for 10 seconds a two tone beep will be heard after 5 seconds followed by 2 sets of two tone beeps after 10 seconds then release The LED will turn on Wh...

Page 3: ...rogram the same Manager Keys to multiple locks Replace Keys Replacement keys must be purchased and programmed to the locks to prevent the lost stolen keys from operating a lock To replace the Programming Key Note the order or serial number found on the lock s rear unit Contact Digilock Support to purchase a replacement Programming Key To replace the Manager Keys Collect all remaining Manager Keys ...

Page 4: ...ts a User RFID Credential or inserts any User Key to lock and the same User RFID Credential or User Key to unlock Once unlocked the lock is available for a different user If a valid Manager Key is used to relock the previous user credential will continue to operate the lock Operate with a User RFID Credential To lock Close the door Press then present any User RFID Credential To unlock Press then p...

Page 5: ... for assistance 2 sets of three beeps The batteries are low Replace the batteries Does not Unlock with the User RFID Credential or User Key The lock does not recognize the User RFID or User Key For immediate access operate with a valid Manager Key Does not Operate with a Manager Key The lock does not recognize the Manager Key Follow instructions to Add Manager Keys and RFID Credentials to program ...