Battery Replacement  

(shown with cable rear unit)

Support

It is not necessary to uninstall the lock from the door. In case of battery failure, operate with a valid Manager Key.

Remove the screws and the cover plate.

Pull the battery pack from the rear housing. 
Replace with four premium alkaline 
AA batteries.

Place the battery pack back into the rear 
housing and screw cover plate in place.

Error Condition Indicators

10  rapid beeps:

The lock is binding, meaning either door alignment or items in the locker are preventing the lock from operating. Press on the door while 
operating the lock. If error condition persists, contact Digilock support for assistance.

2 s ets of three beeps:

The batteries are low. Replace the batteries.

Does not Unlock with the User RFID Credential or User Key

The lock does not recognize the User RFID or User Key. For immediate access, operate with a valid Manager Key.

Does not Operate with a Manager Key

The lock does not recognize the Manager Key. Follow instructions to Add Manager Keys and RFID Credentials to program the Manager 
Key to the lock. For immediate access, operate with another valid Manager Key.

Does not Operate with the Programming Key

The lock does not recognize the Programming Key. If the Programming Key has been replaced, operate with the Replacement 
Programming Key. Contact Digilock support for additional assistance. 

No Audible Feedback when 

=

 is Pressed

 

 The batteries may need to be replaced. For immediate access, operate with a valid Manager Key. 

 

 The front unit may not be properly connected to the rear unit. Remove the lock from the door and check the connection.

1

2

3

030718

Summary of Contents for Next Cue

Page 1: ... unique to the lock system Keys User Key Manager Key Programming Key Operates the lock Overrides user access Allows management inspection Provides external power Programs Manager Keys Sets lock functionality Up to 25 Manager Keys may be programed to each lock 1 Programming Key allowed per lock group NextLock logo must face up Front Unit Key Button Key Slot Reader Rear Unit Key Insertion Cover Plat...

Page 2: ... Manager Credentials The Programming Key can quickly program the same Manager Keys and Manager RFID Credentials to operate multiple locks Go to the lock already programmed to operate with the Manager Keys and Manager RFID Credentials Press and hold for 10 seconds a two tone beep will be heard after 5 seconds followed by 2 sets of two tone beeps after 10 seconds then release The LED will turn on Wh...

Page 3: ...rogram the same Manager Keys to multiple locks Replace Keys Replacement keys must be purchased and programmed to the locks to prevent the lost stolen keys from operating a lock To replace the Programming Key Note the order or serial number found on the lock s rear unit Contact Digilock Support to purchase a replacement Programming Key To replace the Manager Keys Collect all remaining Manager Keys ...

Page 4: ...ts a User RFID Credential or inserts any User Key to lock and the same User RFID Credential or User Key to unlock Once unlocked the lock is available for a different user If a valid Manager Key is used to relock the previous user credential will continue to operate the lock Operate with a User RFID Credential To lock Close the door Press then present any User RFID Credential To unlock Press then p...

Page 5: ... for assistance 2 sets of three beeps The batteries are low Replace the batteries Does not Unlock with the User RFID Credential or User Key The lock does not recognize the User RFID or User Key For immediate access operate with a valid Manager Key Does not Operate with a Manager Key The lock does not recognize the Manager Key Follow instructions to Add Manager Keys and RFID Credentials to program ...

Reviews: