RFID Interface
Bolt Mechanism
Shared Use Functionality
Product Guide
Phone: 707 766 6000
www.digilock.com | sales@digilock.com
PG-NLQR-AD-DEN
Battery Replacement
(shown with cable rear unit)
Support
It is not necessary to uninstall the lock from the door. In case of battery failure, operate with a valid Manager Key.
Remove the screws and the cover plate.
Pull the battery pack from the rear housing.
Replace with four premium alkaline
AA batteries.
Place the battery pack back into the rear
housing and screw cover plate in place.
Error Condition Indicators
10 rapid beeps:
The lock is binding, meaning either door alignment or items in the locker are preventing the lock from operating. Press on the door while
operating the lock. If error condition persists, contact Digilock support for assistance.
2 s ets of three beeps:
The batteries are low. Replace the batteries.
Does not Unlock with the User RFID Credential or User Key
The lock does not recognize the User RFID or User Key. For immediate access, operate with a valid Manager Key.
Does not Operate with a Manager Key
The lock does not recognize the Manager Key. Follow instructions to Add Manager Keys and RFID Credentials to program the Manager
Key to the lock. For immediate access, operate with another valid Manager Key.
Does not Operate with the Programming Key
The lock does not recognize the Programming Key. If the Programming Key has been replaced, operate with the Replacement
Programming Key. Contact Digilock support for additional assistance.
No Audible Feedback when
=
is Pressed
▪
The batteries may need to be replaced. For immediate access, operate with a valid Manager Key.
▪
The front unit may not be properly connected to the rear unit. Remove the lock from the door and check the connection.