background image

Hybrid Inverter Users’ Manual 

Page | 11   

AC Output Over load    (by pass) 

1700-3000W 

AC Output Surge Powe ( by pass) 

3000W 

AC Charger current   

1.1A@230VAC 

1.2A@120VAC 

Charger output voltage ragne   

10~15VDC 

Charger output current   

10A@12VDC±10% 

Max charge voltage   

15VDC±0.3V 

Efficiency  

80% 

Output short circit protection   

OK 

Reverse battery protection 

OK 

Battery high voltage protection 

15VDC±1V 

PV 

Max charge current   

16A±2A 

Solar panle input voltage   

20-50VDC 

Max charge voltage   

15VDC±1V 

Soft Start   

12.8VDC±1V 

MPPT Effciency   

92% 

LCD Display   

Yes 

AC to /DC/ DC to AC   

15ms 

 

Summary of Contents for UP-8B5N

Page 1: ...Hybrid Inverter Users Manual Page 1 1500 WATT HYBRID INVERTER SOLAR INVERTER AC MAINS Users Manual...

Page 2: ...The 230 volt AC can NOT be converted to 12 volt DC to only charge the battery bank that is connected Do NOT place the inverter near flammable materials or any location which accumulate flammable fume...

Page 3: ...Hybrid Inverter Users Manual Page 3 4 Names and Functions Front Panel Power Output and Back Panel Power Input...

Page 4: ...LCD Display switch 5 How to Connect the Hybrid Inverter in Your Facilities 1 Connect the battery terminals with the battery as shown in Step 1 Please ensure the polarity is correct 2 Connect the solar...

Page 5: ...erter and the power source Check the connections with exposed conductive parts Blown fuse in the inverter Replace the fuse No AC output voltage Over temperature protection Check for adequate ventilati...

Page 6: ...ry is old or defective Replace the battery The battery capacity is too small Use a higher capacity battery Charger failure no charge voltage The battery voltage is too low to be charged Change the bat...

Page 7: ...If the battery voltage drops to 12 8 volt the MCU will once again start charging t7 When the load requirement is less than the energy provided by the chargers the battery voltage will climb slowly On...

Page 8: ...load through the battery Users can also press the AC DC priority switch to set the DC first mode as the battery discharges below 15 volt t3 When the battery drops below 12 8 volt the MCU will once ag...

Page 9: ...keep loads running t10 When the battery drops below 12 8 volt the MCU will once again start up the solar charger instead of the AC charger in order to save energy t11 As the battery voltage falls as l...

Page 10: ...120VAC 5V UL Continuous Power 1500W Overload Protection 1650 1900W Alarm 30S Surge Power 3000W Frequency 60 50 0 5Hz Switch Wave Form Pure Sine Wave THD Line load 3 Efficiency 80 Over Temperature Pro...

Page 11: ...ge ragne 10 15VDC Charger output current 10A 12VDC 10 Max charge voltage 15VDC 0 3V Efficiency 80 Output short circit protection OK Reverse battery protection OK Battery high voltage protection 15VDC...