FAQ and Troubleshooting Guide   

Problem 

Possible Cause 

Suggested Action 

Hybrid inverter is not 
working 

The battery is not being charged 
properly. 

Have a qualified technician check 
the battery. Recharge or replace 
the battery. 

Incorrect connections between the 
inverter and the power source 

Check the connections with 
exposed conductive parts. 

Blown fuse in the inverter 

Replace the fuse. 

No AC output voltage 

Over temperature protection 

Check for adequate ventilation. 
Reduce the load on the inverter to 
rated power. 

The load is rated at more than 1500 
watts; an overload protection has 
occurred. 

Ensure the load with a power 
rating less than 1500 watts. Once 
the load exceeds the surge 
capability, please use a load with 
a starting surge power within its 
capability.  

Summary of Contents for UP-8B5N

Page 1: ...Hybrid Inverter Users Manual Page 1 1500 WATT HYBRID INVERTER SOLAR INVERTER AC MAINS Users Manual...

Page 2: ...The 230 volt AC can NOT be converted to 12 volt DC to only charge the battery bank that is connected Do NOT place the inverter near flammable materials or any location which accumulate flammable fume...

Page 3: ...Hybrid Inverter Users Manual Page 3 4 Names and Functions Front Panel Power Output and Back Panel Power Input...

Page 4: ...LCD Display switch 5 How to Connect the Hybrid Inverter in Your Facilities 1 Connect the battery terminals with the battery as shown in Step 1 Please ensure the polarity is correct 2 Connect the solar...

Page 5: ...erter and the power source Check the connections with exposed conductive parts Blown fuse in the inverter Replace the fuse No AC output voltage Over temperature protection Check for adequate ventilati...

Page 6: ...ry is old or defective Replace the battery The battery capacity is too small Use a higher capacity battery Charger failure no charge voltage The battery voltage is too low to be charged Change the bat...

Page 7: ...If the battery voltage drops to 12 8 volt the MCU will once again start charging t7 When the load requirement is less than the energy provided by the chargers the battery voltage will climb slowly On...

Page 8: ...load through the battery Users can also press the AC DC priority switch to set the DC first mode as the battery discharges below 15 volt t3 When the battery drops below 12 8 volt the MCU will once ag...

Page 9: ...keep loads running t10 When the battery drops below 12 8 volt the MCU will once again start up the solar charger instead of the AC charger in order to save energy t11 As the battery voltage falls as l...

Page 10: ...120VAC 5V UL Continuous Power 1500W Overload Protection 1650 1900W Alarm 30S Surge Power 3000W Frequency 60 50 0 5Hz Switch Wave Form Pure Sine Wave THD Line load 3 Efficiency 80 Over Temperature Pro...

Page 11: ...ge ragne 10 15VDC Charger output current 10A 12VDC 10 Max charge voltage 15VDC 0 3V Efficiency 80 Output short circit protection OK Reverse battery protection OK Battery high voltage protection 15VDC...

Reviews: