NTRODUCTION

The Annunciator Module (DGP2-
ANC1B) is a status display device 
that is connected to the control 
panel’s four-wire combus as a stand-
alone module or mounted on a 
keypad. Set the DGP2-ANC1 to 
display the status of up to eight 
partitions, zones 1 to 48 or zones 49 
to 96.

LED F

EEDBACK

P

ROGRAMMING

 M

ETHOD

To program the DGP2-ANC1B, you must enter the Module Programming Mode 
using any keypad in the system. To do so:

1.

Press and hold the 

[0]

 key.

2.

Enter the 

[

INSTALLER

 

CODE

]

.

3.

Enter section 

[4003]

.

4.

Enter the Annunciator’s 8-digit 

[

SERIAL

 

NUMBER

]

 *.

5.

Enter the 3-digit section you wish to program.

Program the DGP2-ANC1B using the WinLoad Software or the control panel’s 
Module Broadcast feature. Refer to the 

Digiplex

 

EVO

 

Programming Guide

 for 

more details. 

*Note: The serial number is located on the module’s PC Board.

Use this option to assign access to partitions. The DGP2-ANC1B will only 
display the status of events that occur in partitions that have been assigned. For 
example, if zone 5 in partition 1 has been breached, but partition 1 is not 
assigned to the DGP2-ANC1B, zone 5 will not be displayed. Keys 

[1]

 to 

[8]

 

represent partitions 1 through 8 respectively*. To assign access to a partition, 
enable the option that corresponds to the desired partition. Partitions 1 to 8 are 
enabled by default.

Enable option

 [1] 

in section 

[002]

 to mute options 

[2] 

to 

[5]

. Disable the mute 

option to enable the use of options 

[2]

 to 

[5]

. This option is disabled by default.

Enable option 

[2] 

in section 

[002]

 to set the Annunciator to emit an intermittent 

trouble beep* every three seconds. Troubles may be:

*Note: Option 

[1] in section [002] must be disabled.

Enable option 

[3]

 in section 

[002]

 to set the Annunciator to emit a beep* when 

these troubles occur:

*Note: Option 

[1] in section [002] must be disabled.

Enable option 

[4]

 in section 

[002]

 to set the Annunciator to emit a beep* when 

these troubles occur:

*Note: Option

 [1] in section [002] must be disabled.

Enable option 

[5]

 in section 

[002]

 to set the Annunciator to emit a beep* when 

these troubles occur:

Zone Tamper 
Low Battery on Wireless Device
Zone(s) affected by: communication, fire loop, or CleanMe™ trouble

*Note: Option 

[1] in section [002] must be disabled.

The trouble beep will stop when the problem is resolved, or if you 
press the 

[

TRBL

key

 

from any keypad on the network. This applies to 

Section

 [002]

, options 

[2]

 to 

[5]

Enter a value between 000 and 005 in section 

[003]

 to set which status the 

Annunciator will display. 

000 = Partition Status (default)003 = Future Use         
001 = Future Use

004 = Zones 01 to 48

002 = Future Use

005 = Zones 49 to 96

S

PECIFICATIONS

Input Voltage:

Typically 11-16Vdc

Compatibility:

EVO48, EVO192 
DGP48, DGP848 
DGP-NE96, EVO96
WinLoad V2.10 or higher 

Current Consumption:

Min:15mA  Typ:50mA  Max:100mA 

B

EFORE

 I

NSTALLING

 

THE

 DGP2-ANC1B

Choose a position where you will mount the Annunciator either as a stand-alone 
module unit (see “Mounting as a Stand-alone Module”), or mounted on a keypad 
(see “Mounting to a Keypad”). Once the module is connected and programmed, 
you can use one of three display labels to reflect the DGP2-ANC1B’s status 
display. Should the system require more than one display, you can “stack” up to 
three DGP2-ANC1Bs. 

Do not remove the DGP2-ANC1B’s guide clip (Figure 1) unless it is 
mounted as a stand-alone module. This clip sets the distance between 
the DGP2-ANC1B and the keypad or other Annunciators (if they are 
“stacked”). If the clip is removed the DGP2-ANC1’s covers cannot be 
placed properly.

Mounting to a Keypad 

1.

Connect one end of the wires to the Annunciator’s network terminals. Do not 
close the back and front covers until you have decided how you will set the 
module.

2.

From the keypad’s back plate, cut out section labelled “E” as shown in 
Figure 2 on page 2.

3.

Loosen keypad’s network terminal screws without disconnecting the wires.

4.

From the Annunciator’s backplate, cut out section labelled “A” as shown in 
Figure 1 on page 2.

Slow flash* Zone Alarm

Fast flash

Zone Tamper

         Flash System not ready

ON

System ready

*

LED flashes until the partition in alarm 

is disarmed

Section [001] - Option [1] to [8]

Partition Assignment

[1]

 ON = Partition 1       

[5]

 ON = Partition 5 

[2]

 ON = Partition 2       

[6]

 ON = Partition 6 

[3]

 ON = Partition 3       

[7]

 ON = Partition 7

[4]

 ON = Partition 4       

[8]

 ON = Partition 8 

Section [002] - Option [1]

Beeper Mute Mode

Section [002] - Option [2]

Beep on System Trouble 

AC Failure
Battery Trouble
Aux. Current Limit
Bell Current limit     

Bell Absent   
ROM Check Error     
RAM Check Error 
Clock loss

Section [002] - Option [3]

Beep on Communicator Trouble

  Annunciator Module V1.1

 

 (DGP2-ANC1B)

  

Instructions

DGP2ANC1-EI02

TLM1                                                       
Fail to Communicate 1
Fail to Communicate 2

Fail to Communicate 3                       
Fail to Communicate 4
Fail to Communicate PC

Section [002] - Option [4]

Beep on Network/Module Trouble

Module Tamper         
Module ROM Check Error                                            
Module Fail to Communicate                 
Printer Trouble                                      
Module AC Failure
Module Battery Failure

Module Supply Output
Missing Keypad
General Failure
Network Overload
Network Com. Error
Missing Module

Section [002] - Option [5]

Zone Trouble

Section [003]

Status Display Mode