Problem
Topic
Condition/Problem
Possible Cause
Corrective Action
Unit’s Internet Protocol (IP) address
does not match network settings.
Use the Elite Configuration Utility
to check and/or modify the IP
address of the unit. The Elite
Configuration Utility can be
downloaded from the Digital
Check website,
The factory default IP address is
192.168.1.101
PC firewall is blocking the network
connection.
Follow configuration instructions
for PC and/or firewall software.
Inkjet
Faint or light printing
1. Build-up of ink on
the cartridge nozzle.
2. Empty cartridge
Remove cartridge and
gently wipe nozzles with a
tissue and replace into the
scanner.
Replace cartridge if
empty.
Section 5
Replacement parts
To obtain replacement parts, call 1-847-446-2285, visit the Digital Check Store at
, or contact your
authorized service provider
.
The following replacement parts are available:
Item
Part Number
Description
FRU-Power Supply
82275943-000
FRU-Power Supply 36 watt-Includes US line
cord. Replacement power supply for Expert
Micro Elite
United States
-Canada
AC line cord
82275723-000
C-5, line cord fits above power supply.
Inkjet Cartridge-one
MS0083
Ink Jet Cartridge-single line -Black
Cable, Ethernet, CAT-
5e, Patch
68729912-000
7-foot Ethernet cable
Return shipping carton
82276015-000
Complete shipping box and internal foam parts.
The following cleaning supplies are available:
Item
Part Number
Description
Canned compressed air
75-0501-900
Carton of 4 cans
Track cleaning spatula
75-0381-907
Pack of 5
Track cleaning card
75-7200-995
Package of 15
Track cleaning wipes
75-1804-907
Package of 80