Cleaning Scan-Head Steps
Note:
This is only performed when document images are unclear, distorted or have a dark line laterally through
every image.
Step Action
Unscrew the nylon screw and gently open the
scanner camera faceplates.
Use the cleaning swab or a clean cloth to wipe
the camera faceplate (the two white strips and
both sides of the camera faceplate section of
the scanner).
Reassemble the scanner components by
replacing the nylon screw, right and left cover
and the wire document guide.
Step Action
Pull out the wire document guide.
Remove the left & right side covers.
The covers lift off vertically.
Note: The swabs are typically used to clean
off the four main drive rollers, but can also
be used on the scanheads if you have a
tough buildup on the glass.