3
Features and Specifications
Features:
• Microprocessor controlled timing
• Discrete I/O (input - output) construction
• Retains all numbers even with power disconnected from unit
• Large illuminated display for easy reading of information day or night
• Self-test mode on all display functions
• Dust & splash-proof keypad with detent (positive feel)
• Hit the tree twice with one or two separate button
• Instant timing cycle reset
• Programmable push-button interrupt time
• Programmable Tap Up/Down feature for the delay (In pushbutton mode 1 or 3)
• Programmable Starting Line Enhancer (
MEGA
75 w/ 4 Stage Timer
only)
• Built-in drivers reaction tester
Specifications:
•
Input Voltage Range: 10 to 18 Volts DC (16 Volt compatible)
•
Operating Temperature Range: 0 to 150 degrees F.
•
Push-button Current: .1 AMPS at 12 VDC
• Two Separate Inputs
• P.B. 1
• P.B. 2 or Tap P.B.
The Terminal Strip
+12VDC Terminal:
Connect the +12VDC terminal to a sw12 Volt source with enough amperage
capable of driving all outputs at the same time.
Transbrake Terminal:
Connect the Transbrake terminal to the Transbrake solenoid.
Connect the low side of the 2-Step here, if used.
Ground Terminal:
Connect the Ground terminal to the Neg. terminal on the battery or to good steel
ground,
not aluminum.
PB-1 Terminal:
In Push-button Mode 3 the push-button connected to PB-1 terminal is used
to control the primary delay and the secondary delay in sequence. In Push-button Mode 1 & 2
the push-button connected to PB-1 terminal is used to control the primary delay only.
PB-2 Terminal:
In
Push-button Mode 2 the push-button connected to PB-2 terminal is
used to control the secondary delay only.
In Push-button Mode 1 & 3 this terminal can be used for a Tap
pushbutton connection. After a Transbrake push-button has been released, every time the Tap push-button is
depressed a programmable amount of time is either added to, or subtracted from, the first delay time started until the
transbrake is released.
Throttle Stop Terminal:
Connect throttle stop wire to this terminal. This can be used as a
starting line enhancer or down track throttle stop controller.
This is only on the
MEGA
75
w/ 4 Stage Timer.