6–29
Chapter 6 – Initializing the GLC
GLC2300 Series User Manual
WATCHDOG TIMER
Sets the Watchdog Timer (WDT) for the Controller Operation Time and the GLC Operation
Time functions to between 100 and 3000 ms. Input the value in units of 100 ms.
CONTROLLER SETTING 2
ENABLE I/O
This setting allows you to enable the I/O.
CHANGE SCREEN CHECK
After #Screen is used to perform the screen change, the #Screen setting value is
reset to "0". Using the ON (initial) setting will clear the #Screen value to "0".
Refer to the
Pro-Control Operation Manual
(included in the
GP-PRO/PB III C-Package).
6.6
INITIALIZE MEMORY
This section explains how to initialize the GLC unit’s internal memory (screen
data), or how to initialize a CF card inserted in the GLC. Select one of the menu
items, [INITIALIZE MEMORY], [INITIALIZE CF CARD] and [CSV DATA
INDEX].
6.6.1 INITIALIZE MEMORY
This will erase all GLC screen data (internal memory). Back up SRAM will also
be initialized.
•
You cannot cancel the Initialization procedure after pressing START.
Do NOT turn the power off when initializing.
•
All data in SRAM will be erased.
•
Initialization does not erase the SYSTEM SET UP, the SIO protocol, or
the internal clock settings.
To initialize the GLC internal memory, enter the default password,
1101,
or the
password entered in the
SYSTEM SETUP
screen.
See
5.3 – “INITIALIZATION.”
The time required for Initialization is between 10 and 20 sec-