Installation and Handling Instructions
7
If the heatsink retaining clip is used, install it properly by hooking its
ends around the ZIF socket retainers.
D.3
SIMM Installation and Removal Instructions
1
Observe antistatic handling precautions.
2
Five types of SIMMs are supported on the AXPpci 33. SIMMs must
be installed in pairs consisting of identical devices. It is recommended
that all SIMMs be purchased from the same vendor. See Table A–3
for supported SIMM sizes. SIMM pairs in banks 0 and 1 can be of
different sizes.
3
To prevent damage, only handle SIMMs at the edges.
4
The first pair of SIMMs can be installed in either bank 0 or 1.
5
To install:
a.
Hold the SIMM at an angle with the notch facing the key in the
socket.
b.
Firmly push the module into the connector and stand the module
upright.
c.
Make sure that the SIMM snaps into the metal locking clips on
both ends.
6
To remove:
a.
Release the spring clips at both ends of the SIMM by gently
pushing out the clips.
b.
Holding the module by its edge, tilt the module forward and
remove.
c.
Temporarily place SIMMs on antistatic material or store them in
an antistatic bag.
Figure D–3 shows how to install a SIMM.