Removing and Replacing Field Replaceable Units
3.17 Removing the CPU Module
9. Disconnect the SCSI ribbon cable (17-02944-01) from the CPU module
(refer to Figure 3–44).
Caution
Ensure that you do not damage any of the CPU module components by
exerting too much force on the components.
10. Press the two spring clips (marked by arrows in Figure 3–45) that secure
the CPU module in position. The CPU module moves forward under the
tension of the connector gaskets. If necessary, slide the CPU module back
until it disengages from the ten keyhole cutouts (refer to Figure 3–45).
11. Use your finger, in the semicircular cutout on the front edge of the CPU
module, to lift up the front edge of the CPU module (refer to Figure 3–45).
12. While supporting the front of the CPU module with one hand, guide the
connectors on the back of the CPU module out of the corresponding cutouts
on the back of the enclosure.
13. Remove the CPU module from the enclosure.
3–70 Removing and Replacing Field Replaceable Units